Product Specifications
Power: 230V AC units: 50 Hz, Current 120 mA max.
Sensor: CO sensor calibrated at 150 ppm (±25 ppm).
Temperature: Operating range: 40˚F (4.4˚C) to 100˚F (37.8˚C).
Mounting: Accessories supplied for wall mount or direct plug applications.
Alarm: 85+ dB at 10’ @ 3.4 ± 0.5 KHz pulsing alarm. In alarm condition for CO you will hear a repeating pattern of quick beeps.
LED Operation: Blinking dot on display denotes normal operation. Display readings from
Green LED is on constantly while the unit is powered with 230 volts and flashes every 15 seconds while on battery backup.
Yellow LED flashes when the battery is low and is on constantly when the alarm malfunctions.
Battery Backup:
A 9 volt battery is needed. If battery is low or missing while the unit is plugged into a 230V outlet, an “Lb” message will display which will blink alternately with a the CO reading every second and the sounder will chirp every 15 seconds.
Unit Malfunction:
“Err” error message will display. Intermittent alarm will sound every 30 seconds.
Test/Reset Button:
Test button verifies proper unit operation and resets the unit in the event of a CO Alarm.
Peak Level Memory Button:
When pressed, LED will display the highest CO ppm level detected since unit was powered up or since unit was reset with test button. Reading will be stored in memory as long as unit is not reset or unplugged. Any CO concen- tration detected from
Size: 15.2 cm (6”)L x 3.75”W x 1.8”H. Wt. 1 lb.
Warranty: