4.The maximum wire run distance between the first and last device in an inter- connect system is 1000 ft.

5.Figure 1 illustrates interconnection wiring. Improper connection will result in damage to the strobe light or alarms, failure to operate, or a shock hazard.

6.Make certain that all devices in the interconnect system are wired to a contin- uous (non-switched, non-GFI or GCFI protected) power line.

FUSE OR CIRCUIT BREAKER

L

N

WIRE NUT

 

 

 

 

 

 

 

OR

 

 

 

 

 

 

 

EQUIVALENT

RED

 

RED

 

RED

 

RED

 

 

 

 

BLACK

WHITE

BLACK

WHITE

BLACK

WHITE

BLACK

WHITE

 

 

 

SMOKE ALARM

STROBE LIGHT

HEAT ALARM

CO ALARM

 

 

 

FIGURE 1

 

 

 

 

FIGURE 1: INTERCONNECT WIRING DIAGRAM FOR SL177i.

WIRE ON STROBE LIGHT HARNESS CONNECTED TO: BLACK . . . . . . . . . .HOT SIDE OF AC LINE

WHITE . . . . . . . . . .NEUTRAL AC LINE

RED . . . . . . . . . . . .INTERCONNECT LINES (RED WIRES) OF THE OTHER UNITS IN THE MULTIPLE STATION SET UP

FUSE OR CIRCUIT BREAKER

SWITCHING DEVICE USED TO CONTROL THE OPERATION OF THE SL177 STROBE LIGHT

WIRE NUT OR

EQUIVALENT

WHITE BLACK

FIGURE 2