Kidde SL177i Architectural and Engineering Specifications, Technical Specifications, Gift Box UPC

Models: SL177i

1 2
Download 2 pages 20.51 Kb
Page 2
Image 2
120VAC Dual Mode Strobe Light

120VAC Dual Mode Strobe Light

Unit Number SL177i

for the Hearing Impaired

 

 

 

Architectural and Engineering Specifications

The strobe light shall be Kidde Unit SL177i or approved equal. It shall be powered by a 120VAC, 60Hz source. The temperature operation range shall be between 40°F and 100°F (4°C and 38°C). The strobe light can be installed on any standard single gang electrical box, up to a 4” octagon junction box. The electrical connection (to the alarm) shall be made with a plug-in connector. A maximum of 24 Kidde devices can be interconnected in a multiple station arrange- ment. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices (Smoke, heat, CO, etc) interconnected, it is still possi- ble to interconnect 6 strobe lights and or relay modules. The alarm shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling.

This unit shall include a bright candela strobe light with a flash rate of one (1) flash per second. This unit shall be interconnected with Kidde smoke alarms, heat detectors and/or carbon monoxide alarms. The unit shall at a minimum meet the requirements of UL217, NFPA72, (chapter 10 & 11 2002 edition) The State of California Fire Marshall, NFPA101 (One and two family dwellings, Federal Housing Authority (FHA), Housing and Urban Development (HUD), Americans with Disabilities Act (ADA).

Technical Specifications

Unit Number:

SL177i

UPC:

0-25417-19129-5

 

 

Power Source:

120VAC, 60HZ

 

 

Temperature Range:

40˚F to 100˚F (4˚C to 38˚C)

 

 

Size:

5.6” in diameter x 3” depth

 

 

Weight:

1lb

 

 

Interconnects:

Up to 24 Kidde devices

 

 

Warranty:

5 year limited warranty

 

 

Installation of Strobe Light

The strobe light should be installed to comply with all local codes having jurisdiction in your area, Article 760 of the National Electric Code, and NFPA 72. Make certain all alarms are wired to a single, continuous (non-switched) power line, which is not protected by a ground fault interrupter. A maximum of 1000 ft. of wire can be used in the interconnect system.

5.6"

3"

Ordering Information

Gift Box UPC:

0-25417-19129-5

 

 

 

 

 

 

Part

 

 

Dimensions

 

Case/

Layers/

Skid

Number

I 2 of 5

Pack Quantity

(w x d x h inches)

Weight

Skid

Skid

Weight

 

 

 

 

 

 

 

 

SL177i

N/A

Individual

5.75 x 3.25 x 6.75

1lb

N/A

N/A

N/A

 

 

 

 

 

 

 

 

SL177i

200 25417 19129 9

3 units

6.5 x 10.5 x 6.5

3lbs

120

5

360lbs

 

 

 

 

 

 

 

 

Distributed by:

1394 South Third Street, Mebane NC 27302

1-800-880-6788 • www.kiddeus.com