Breckwell Breckwell Hearth Products LUXURY SERIES Installation, Specifications, Preparation

Models: Breckwell Hearth Products LUXURY SERIES P2700

1 26
Download 26 pages 56.62 Kb
Page 5
Image 5
INSTALLATION

INSTALLATION

SPECIFICATIONS

Width: 23 1/8”

Height: 30 ½”

Depth: 22 ¼”

Weight: 233 lbs.

Flue size: 3” or 4”

Hopper Capacity: Up to 50 lbs.

(This can vary widely depending on pellet size, length, and diameter)

EPA status: exempt

Burn time: 1 lb. to 5.5 lbs. per hour

BTU range: 8,200 to 50,000

Approved installations: mobile home, alcove, conventional

 

 

FIGURE 1

PREPARATION

 

 

 

 

 

 

5

Factory packaging must be removed, and some minor assembly work is required prior to installation. Access to the rear of the stove is necessary.

NOTE: Normally, your dealer will perform these functions.

CLEARANCES

The Breckwell P2700 Freestanding has been tested and listed for installation in residential, mobile home and alcove applications.

FLOOR PROTECTION: Freestanding installations, minimum 24” wide by 29” deep. The stove must be placed on a continuous (grouted joints) noncombustible material such as ceramic tile, cement board, brick, 3/8” millboard or equivalent, or other approved or listed material suited for floor protection. NOTE: ceramic tile, or any tile, requires a continuous sheet beneath to prevent the possibility of embers falling through to the combustible floor if cracks or separation should occur in the finished surface, this would include floor protection for Built-in raised hearths. Check local codes for approved alternatives.

Clearances are measured from the sides, back and face (door opening) or stove body (refer to fig. 3).

DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE INSTALLATION OF THIS UNIT.

INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

FIGURE 2

FLOOR PROTECTION

(MINIMUM 24” W X 29” D)

FIGURE 3

Page 5
Image 5
Breckwell Breckwell Hearth Products LUXURY SERIES Installation, Specifications, Preparation, Clearances, Floor Protection