Operating/Installation Instructions

there is a location that has ‘Replace by’ printed on it. Remove mounting plate from the back of the unit by holding the rim of the mounting plate and twisting counterclockwise (left). Write the replace-by date on the label. The date written on the label should be seven (7) years after the date the unit is initially powered up.

Hold the mounting plate against the selected installation location (wall or ceiling) and mark the centre of the holes with a pencil. To ensure aesthetic alignment of the alarm with the hallway, or wall, the “A” line on the mounting plate must be parallel with the hallway when ceiling mounting, or horizontal when wall mounting. Drill a hole through the pencil marks and use the enclosed screws and anchors to secure (use 5mm drill bit for anchor holes). Align the Smoke/CO Alarm with the mounting plate and rotate clockwise (right) until the unit is aligned.

When mounting in the hallway, the "A" line should be parallel with the hallway.

AA

Alignment Marks

FIGURE 1

Remove

Install

Two labels are included with your alarm. They have important information on what to do in case of an alarm. Add the phone number of your emergency service provider in the space provided. place one label next to the alarm after it is mounted, and one label near a fresh air source such as a door or window.

D. Tamper Resist Feature:

To make your smoke alarm somewhat tamper resistant, a tamper resist feature has been provided.

15

Page 15
Image 15
Kidde SMOKE AND CARBON MONOXIDE ALARM installation instructions Tamper Resist Feature