12 | Appendix B Cabling Guidelines |
UTP Cable Rating Codes
UTP cables meet different
UL – The National Electrical Code (NEC), published by the National Fire Protection Association (NFPA), details advisory safety considerations for electrical wiring. NEC Article 800 Communications Cables are manufactured to meet these different cable types.
1.CMP – Cables meeting type CMP requirements are suitable for installation in ducts and plenums without the use of conduit. These cables are designed for fire resistance and
2.CMR – Riser type cables are engineered to prevent the spread of fire from floor to floor and are suitable for vertical shaft applications.
3.CM – Cables for general building wiring. CM cables are used in areas other than plenums and risers. These cables are resistant to the spread of fire and pass the UL 1581Vertical Tray Flame Test.
4.MP, MPR & MPP – Within Article 800, the
Terms You Should Be Familiar With
1.BACKBONE WIRING – The physical/electrical interconnections between telecommunications wiring closets and equipment rooms.
2.COMPLIANCE – A datacomm or wiring device that meets all characteristics of a standard is said to be in compliance with that standard.
3.PREMISE WIRING – The entire wiring system on the premises, especially the supporting wiring that connects the communications outlets to the network interface jack.
PJ
Kingston Technology Company | KNS1600/R User’s Guide - Rev. A00 |