ran es:

countertop preparation

30 _

(76.2 cm)

opening,1/2" width

p"

30-7/8"

(78.4 cm) Formed or tiled countertop

. /trimmed 1/2" (1.3 cm)back at front corners of

countertop opening.

(63.5 cm)

Cooktop sides of range fit over edges of countertop opening.

for

ation:

Assemble the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

level

Phillips scewdriver

fiat-blade screwdriver or 5/16""(7.9 mm) nut driver 3/8" ( 9.5 mm) ratchet

adjustable wrench pliers

hammer

The cooktop sides of the siidedn range fit over the cutout edge of your countertop.

if you have a square finish (flat) countertop and the opening width is 30" (76.2 cm), no countertop preparation is required.

Formed front-edged countertops: Must have molded edge shaved flat 1/2" (1.3 cm) from each front corner of opening.

Tile countertops may need trim cut back 1/2" (1.3 cm) from each front corner andlor rounded edge flattened.

if countertop opening width is greater than

30" (76.2 cm), adjust the 1/2" (1.3 cm) dimension.

Countertop must be level. Place level on countertop, first side to side; then front to back. if countertop is not level, range will not be level

Oven must be level for satisfactory baking conditions.

measureing tape or ruler hand or electric drill

wood floor: 1/8" (0.3 cm) drift bit

concrete/ceramic floor: 3/16" (0.48 cm) carbide-tipped masonry drill bit

LR gas conversion requires: pin pick up (claw attachment)

5/16" nut driver

arts sup for

uct dimensions

Freestanding Range

30" (76.2 cm) range width

36-1/8"

(91.8 cm) cooktop height

44-3/8"

(112.7 cm)

-4

27-3/4"

(70.5 cm)

depth with

handle

Slide-in Range

]

1-1/2"

30"

(76.2

cm) _1

 

rear

vent

width

n:

burner grates and caps

vent cap

LR conversion orifice spud kit:

1- 0.95 mm (0.0374") cooktop (blue)

2 - 0.67 mm (0.0264") cooktop (black)

1- 1.05 mm (0.0413") cooktop (green)

1-#65 (0.0350") broil burner

anti-tig

plastic anchors

(#10 x 1-1/2")

(Bracket must be securely mounted to sub-floor. Thickness of flooring may require longer screws to anchor the bracket to sub-floor.)

Mobile home installation

The installation of this range must conform to the Manufactured Home Construction and Safety

Standards, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and

Safety, Title 24, HUD, Part 280); or when such standard is not applicable, the Standard for Manufactured Homes installations (Manufactured Home Sites, Communities and Setups), ANSI A225.1/NFPA 501A*, or with local codes.

(3.8 cm)

(2.54 cm) spacer

27-3/4"

iMPORTANT:

Rear vent must be installed on aJJ slide-in models for proper ventilation. See Step 7, Panel D.

36-1/8"

(91.8 cm) cooktop height

30 _

(76.2 cm) width

In Canada, the installation of this range must conform with the current standards CAN/CSA-Z240 -- latest

edition**, or with local codes.

When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.

Copies of the standards listed may be obtained from: * National Fire Protection Association

One Batterymarch Park Quincy, Massachusetts 02269

**CSA International

8501 East Pleasant'Valley Road Cleveland, Ohio 44131-5575

The floor anti-tip bracket must

(70.5 cm) ...

depth

with handle

be installed. To install the anti-tip bracket shipped with the range, see Panel D and the anti-tip bracket template.

Panel B

Page 3
Image 3
KitchenAid 9755235 Ation, Uct dimensions, Countertop preparation, Freestanding Range, Slide-in Range