30" Freestanding and Slide-In Dual Fuel Range®

PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS

KDRS807S KDSS907S

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

The cooktop sides of the slide-in range fit over the

cutout edge of your countertop.

If you have a square finish (flat) countertop and the

opening width is 30" (76.2 cm), no countertop

preparation is required.

Formed front-edged countertops must have molded

edge shaved flat 3/8" (1.0 cm) from each front corner

of opening.

Tile countertops may need trim cut back

3/8" (1.0 cm) from each front corner and/or rounded

edge flattened.

If countertop opening width is greater than

30" (76.2 cm), adjust the 3/8" (1.0 cm) dimension.

Countertop must be level. Place level on countertop,

first side to side; then front to back. If countertop is

not level, range will not be level. Range must be level

for satisfactory baking conditions.

Gas supply:Provide a gas supply line of 3/4"

(1.9 cm) rigid pipe to the range location. A smaller

size pipe on longer runs may result in insufficient

gas supply. Pipe-joint compounds that resist the

action of LP gas must be used. Do not use

TEFLON®tape. With LP gas, piping or tubing size

can be 1/2" (1.3 cm) minimum. Usually, LP gas

suppliers determine the size and materials used in

the system. If local codes permit, a new CSA

design-certified, 4' - 5' (122 - 152.4 cm) long,

1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., flexible metal

appliance connector may be used for connecting

range to the gas supply line. A 1/2" (1.3 cm) male

pipe thread is needed for connection to the female

pipe threads of the inlet to the appliance pressure

regulator. The supply line must be equipped with a

manual shutoff valve. This valve should be located

in the same room but external to the range. It

should be in a location that allows ease of opening

and closing.

Electrical:When a 4-wire or 3-wire, single phase

120/240 volt, 60 Hz, AC only electrical supply is

available, a 50-amp maximum circuit protection is

required. When a 4-wire or 3-wire single phase

120/208 volt 60 Hz, AC only electrical supply is

available, a 40-amp maximum circuit protection is

required, fused on both sides of the line. A separate

circuit is recommended. A time-delay fuse or circuit

breaker is recommended.

Ref. W10154991
06-24-08
Freestanding Range Slide-in Range
30"
(76.2 cm)
30"
(76.2 cm)
30-9/16"
(77.6 cm)
5-3/4"
(14.6 cm)
36" (91.4 cm)
cooktop trim
height with
leveling legs
screwed all
the way in*
35-5/8" (90.5 cm)
height to underside
of cooktop edge
with leveling legs
screwed all
the way in*
41-3/4"
(106 cm)
overall height
with leveling
legs screwed
all the way in*
Model/serial number
plate (located on the
right-hand side
oven door trim)
27-1/4"
(69.2 cm) max.
from handle to
standoff at
back of range**
27-1/4"
(69.2 cm) max.
from handle to
standoff at
back of range**
23" (58.4 cm)
countertop
notch to rear
of countertop
Model/serial
number plate
(located on the
right-hand side
oven door trim)
30"(76.2 cm)30 ¾"(78.1 cm)³⁄₈"(1.0 cm)

*Range can be raised approximately 1"

(2.5 cm) by adjusting the leveling legs.

**When installed in a 24" (61 cm) base cabinet

with 25" (63.5 cm) countertop; front of oven

door protrudes 1" (2.5 cm) beyond 24"

(61 cm) base cabinet.

*Range can be raised approximately 1"

(2.5 cm) by adjusting the leveling legs.

**When installed in a 24" (61 cm) base cabinet

with 25" (63.5 cm) countertop; front of oven

door protrudes 1-3/4" (4.4 cm) beyond

24" (61 cm) base cabinet.

SLIDE-IN COUNTERTOP PREPARATION

INSTALLATION CLEARANCES

18" (45.7 cm)
upper cabinet
to countertop
18" (45.7 cm)
upper cabinet
to countertop
13" (33 cm) upper
cabinet depth
13" (33 cm) max.
upper cabinet depth
30" (76.2 cm) min.
opening width
30" (76.2 cm) min.
opening width
For minimum
clearance to top
of the cooktop,
see NOTE.
For minimum
clearance to top
of the cooktop,
see NOTE.
30" (76.2 cm)
min. opening
width
30" (76.2 cm)
min. opening
width
This shaded area
recommended for
installation of
rigid gas pipe.
This shaded area
recommended
for installation
of outlet or
junction box.
This shaded area
recommended
for installation
of outlet or
junction box.
Available
area for
gas and
electric
installation.
8"
(20.3 cm)
6"
(15.2 cm)
6"
(15.2 cm)
8"
(20.3 cm)
7" (17.8 cm)
7" (17.8 cm)
1-1/2"
(3.8 cm)
1-1/2"
(3.8 cm)
4-1/2"
(11.4 cm)
4-1/2"
(11.4 cm)
4-1/2"
(11.4 cm)
4-1/2"
(11.4 cm)
5" (12.7 cm) min.
clearance from
both sides of the
range to the side
wall or other
combustible
material.
5" (12.7 cm) min.
clearance from
both sides of the
range to the side
wall or other
combustible
material.
Cabinet door
or hinge
should not
extend into
the cutout.
Cabinet door
or hinge
should not
extend into
the cutout.
3/4" (1.9 cm)
radius both corners
22-15/16" (58.3 cm)
opening depth
This shaded area
recommended for
installation of
rigid gas pipe. Available
area for
gas and
electric
installation.
segnaR nI-edilSsegnaR gnidnatseerF

NOTE:

24" (61 cm) minimum when bottom of

wood or metal cabinet is protected by

not less than 1/4" (0.64 cm) flame

retardant millboard covered with not

less than No. 28 MSG sheet steel,

0.015" (0.4 mm) stainless steel,

0.024" (0.6 mm) aluminum or 0.020"

(0.5 mm) copper.

30" (76.2 cm) minimum clearance

between the top of the cooking

platform and the bottom of an

unprotected wood or metal cabinet.

If installing a range hood or

microwave hood combination above

the range, follow the range hood or

microwave hood combination

installation instructions for

dimensional clearances above the

cooktop surface.