® Pro Line® Front-Loading Gas Dryer
PRODUCT MODEL NUMBERS
KHGV01R
OVERALL DIMENSIONS
Electrical: A 3 or 4 wire, single phase, 120/240 volt 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate
Exhaust venting: Exhaust your dryer to the outside. Four inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust.
42"**
(106.7 cm)
33"*
(83.8 cm)
57" (144.8 cm)
*Includes door handle
**Includes feet extended 1" (2.5 cm)
NOTE: Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See Installations Instructions, “Venting Requirements.”
27"
(68.6 cm)
UNDERCOUNTER INSTALLATION
Dimensions shown are for minimum spacing.
1" |
(2.5 cm) |
RECESSED AREA AND CLOSET INSTALLATION WITH OR WITHOUT PEDESTAL
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
42" min. (106.7 cm)
1" |
|
|
|
|
| 27" |
|
|
| 1" |
(2.5 cm) |
|
| (68.6 cm) |
|
| (2.5 cm) | ||||
|
|
EXHAUST VENTING
Recommended hood style
B
Angled hood style is |
1" | 27" | 1" |
(2.5 cm) | (68.6 cm) | (2.5 cm) |
| A |
|
| 3"* |
| (7.6 cm) |
48 in.2* |
|
(310 cm2) |
|
24 in.2* | 3"* |
(155 cm2) | |
| (7.6 cm) |
| 1" | 33" |
|
| 5" |
|
(2.5 cm) | (83.8 cm) (12.7 cm) | |||||
|
| B |
| C |
|
|
|
|
| acceptable. | |
A |
|
|
|
|
|
|
|
|
|
|
| 4" |
|
|
|
| 4" |
| (10.2 cm) |
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
| (10.2 cm) |
|
| ||
| 4" |
|
|
|
| 2.5" |
|
|
|
|
| (6.4 cm) | |
(10.2 cm) |
|
| ||||
A. Louvered hood style |
|
| ||||
B. Box hood style |
|
| ||||
Vent system chart 1 - rigid metal vent only |
| |||||
Number of | Type of | Box or | Angled | |||
90º turns | vent | louvered | hoods | |||
or elbows |
|
|
|
| hoods |
|
0 | Rigid metal | 174 ft (53.0 m) | 168 ft (51.2 m) | |||
|
|
|
|
|
|
|
1 | Rigid metal | 164 ft (50.0 m) | 158 ft (48.0 m) | |||
|
|
|
|
|
|
|
2 | Rigid metal | 154 ft (46.9 m) | 148 ft (45.1 m) | |||
|
|
|
|
|
|
|
3 | Rigid metal | 145 ft (44.2 m) | 139 ft (42.4 m) | |||
|
|
|
|
|
|
|
4 | Rigid metal | 137 ft (41.8 m) | 131 ft (39.9 m) | |||
|
|
|
| |||
Vent system chart 2 - rigid metal vent used with a | ||||||
maximum of 8 ft (2.4 m) flexible metal vent |
| |||||
|
|
|
|
|
|
|
Number of | Type of | Box or | Angled | |||
90º turns | vent | louvered | hoods | |||
or elbows |
|
|
|
| hoods |
|
|
|
|
|
|
|
|
0 | Rigid metal | 144 ft (43.9 m) | 138 ft (42.1 m) | |||
|
|
|
|
|
|
|
1 | Rigid metal | 134 ft (40.8 m) | 128 ft (39.0 m) | |||
|
|
|
|
|
|
|
2 | Rigid metal | 125 ft (38.1 m) | 119 ft (36.3 m) | |||
|
|
|
|
|
|
|
3 | Rigid metal | 117 ft (35.7 m) | 111 ft (33.8 m) | |||
|
|
|
|
|
|
|
A. Front view
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
7"* (17.8 cm) | 7"* (17.8 cm) |
Recommended installation spacing for cabinet installation
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
1" | 27" | 1" | 5" | 33" | 1" |
(2.5 cm) (68.6 cm) (2.5 cm) (12.7 cm) (83.8 cm) (2.5 cm) | |||||
| A |
|
| B | C |
A. Front view
B. Side view
C. Cabinet with vents
•Select the route that will provide the straightest and most direct path outdoors.
•Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
•Do not use vent runs longer than specified in vent length chart.
•Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. 3957653 |
Instructions packed with product. Specifications subject to change without notice. |