® | 30” and 36” |
|
PRODUCT MODEL NUMBERS
KHTU705RKHTU705S
KHTU765RKHTU765S
Range Hoods
OVERALL DIMENSIONS
5 ⁷⁄₈" (14.9 cm) dia. exhaust collar
Electrical:
9 ¹⁵⁄₁₆"
Interchangeable front trim
INSTALLATION CLEARANCES
(25.2 cm)
20 ³⁄₁₆”
(51.3 cm)29 ¹⁵⁄₁₆” (76.0 cm) - 30” (76.2 cm) model 35 ¹⁵⁄₁₆” (91.3 cm) - 36” (91.4 cm) model
30”(76.2 cm) or
36” (91.4 cm) min.
cabinet opening width
24” (61 cm) min.
30” (76.2 cm)
suggested max. bottom of hood to cooking surface
18” (45.7 cm) min. clearance upper cabinet to countertop
36” (91.4 cm)
countertop
height
70⁵⁄₁₆"
(178.6 cm)
min.
76⁵⁄₁₆"
(193.8 cm)
max.
to bottom of cabinet frame
VENT AND ELECTRICAL OPENINGS AND MOUNTING SCREW LOCATIONS
| 5⁷⁄₈” | Centerline of | 9¹⁄₈” |
| exhaust collar | ||
| (14.9 cm) | (23.2 cm) | |
|
| ||
1¹⁄₄” | dia. |
| 1³⁄₁₆” |
|
| ||
(3.2 cm) |
|
| |
|
| (3.0 cm) | |
|
|
|
1⁵⁄₁₆”
(3.3 cm)
3⁵⁄₁₆” (10.0 cm)
1⁵⁄₁₆” |
| Centerline of | |
(3.3 cm) |
| ||
7¹⁄₂” | hood | ||
| |||
|
| ||
Electrical | (19.0 cm) |
| |
|
| ||
knockouts |
|
|
VENTING REQUIREMENTS
This range hood is factory set for vented installations. Vent system can terminate through either the roof or a wall. The vent system length should not exceed 35 ft (10.7 m)
It is recommended that you use round vent instead of rectangular vent, especially if elbows are required.
For best performance, use no more than three 90° elbows. If more than one elbow is used, make sure that there is a minimum of 24 inches (61 cm) of straight vent between any two elbows. Do not install two elbows together.
To calculate the length of system you need, add the equivalent feet (meters) from chart below for each vent piece that will be needed.
Determine the length of the vent system you need
To calculate the length of the vent system you need, add the equivalent feet (meters) from chart below for each vent piece that will be needed.
Recommended standard 6” (15.2 cm) fittings
1 ft. round=
1 ft. (0.3 m)
90° elbow= 5 ft. (1.5 m)
45° elbow= 2.5 ft. (0.8 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 9763384