PERFORMANCE DATA SHEETS

Base Grille Water Filtration System

Model T2WG2L/T2RFWG2 Capacity 200 Gallons (758 Liters)

Model T2WG2/T2RFWG2 Capacity 200 Gallons (758 Liters)

System tested and certified by NSF International against NSF/ANSI

Standard 42 for the reduction of Chlorine Taste and Odor, Particulate

Class II*; and against NSF/ANSI Standard 53 for the reduction of Mercury,

Benzene, Toxaphene, O-dichlorobenzene, and Carbofuran.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50% reduction

2.0182 mg/L

2.0 mg/L ± 10%

0.06 mg/L

0.0536 mg/L

97.03

97.34

Particulate Class II*

85% reduction

1333333 #/mL

At least 10,000 particles/mL

6600 #/mL**

2325 #/mL

99.51

99.83

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead: @ pH 6.5***

0.010 mg/L

0.1533 mg/L

0.15 mg/L ± 10%

0.0005 mg/L

0.0005 mg/L

99.67

99.67

Lead: @ pH 8.5***

0.010 mg/L

0.1400 mg/L

0.15 mg/L ± 10%

0.0007 mg/L

0.0006 mg/L

99.50

99.57

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.0058 mg/L

0.006 mg/L ± 10%

0.0002 mg/L

0.0002 mg/L

96.54

96.54

Mercury: @ pH 8.5

0.002 mg/L

0.0059 mg/L

0.006 mg/L ± 10%

0.0005 mg/L

0.0003 mg/L

91.57

94.92

 

 

 

 

 

 

 

 

Benzene

0.005 mg/L

0.0154 mg/L

0.015 mg/L ± 10%

0.0012 mg/L

0.0006 mg/L

92.22

96.34

 

 

 

 

 

 

 

 

O-Dichlorobenzene

0.6 mg/L

1.7571 mg/L

1.8 mg/L ± 10%

0.0250 mg/L

0.0066 mg/L

98.58

99.63

 

 

 

 

 

 

 

 

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 mg/L ± 10%

0.001 mg/L

0.001 mg/L

93.33

93.33

 

 

 

 

 

 

 

 

Carbofuran

0.04 mg/L

0.0819 mg/L

0.08 mg/L ± 10%

0.0400 mg/L

0.0213 mg/L

51.13

74.00

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Use replacement filter T2RFWG2, part #4396841. In Canada, use replacement filter T2RFWG2, part #4396841B.

2008 suggested retail price of $39.99 U.S.A./$49.99 Canada. Prices are subject to change without notice.

Model T2WG2L: Style 1 – Press FILTER to check the status of your water filter. If the filter indicator light is yellow, order a new filter. If the filter indicator light is red, it is recommended that you replace the filter.

Style 2 – When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter.

Style 3 – When the water filter status display changes from “GOOD” to “ORDER,” order a new filter. When the filter indicator reads “REPLACE,” it is recommended that you replace the filter.

Model T2WG2: Change the water filter every 6 months depending upon your usage. If the water flow to the water dispenser or ice maker decreases noticeably before 6 months have passed, replace the water filter more often.

These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Refer to the “Assistance or Service” section for the Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8°C)

Service Flow Rate

0.85 gpm (3.2 Lpm) @ 60 psi

 

 

*Class II particle size: 1 um to <5 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

***Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc. ® NSF is a registered trademark of NSF International.

13

Page 13
Image 13
KitchenAid KSRK25FVBL installation instructions Performance Data Sheets, Application Guidelines/Water Supply Parameters