Location Requirements

WARNING

Dryer Dimensions

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

You will need

A location that allows for proper exhaust installation. See

“Venting Requirements.”

42"**

(106.7 cm)

33"*

(83.8 cm)

57" (144.8 cm)

27"

(68.6 cm)

A separate 30 amp circuit.

If you are using a power supply cord, a grounded electrical

outlet located within 2 ft (61 cm) of either side of the dryer.

See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 250 lbs

(113.4 kg). The combined weight of accessories, clothes

loads and companion appliances should also be considered.

A level floor with a maximum slope of 1" (2.5 cm) under entire

dryer. Clothes may not tumble properly and automatic sensor

cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at

least 18" (46 cm) above the floor. If using a pedestal, you will

need an additional 7" (17.8 cm).

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

Installation spacing

*Includes the door handle.

**Includes the feet extended 1" (2.5 cm). The optional decorative mat (included) will add approximately ½" (1.3 cm) to the height.

NOTE: Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Recommended installation spacing for custom undercounter installation, dryer only

1"

(2.5 cm)

42" min. (106.7 cm)

1"

 

 

 

 

 

27"

 

 

 

1"

(2.5 cm)

 

 

(68.6 cm)

 

 

(2.5 cm)

 

 

Recommended installation spacing for recessed or closet installation, with or without a pedestal

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides, front and rear. Recommended spacing should be considered for the following reasons:

The location must be large enough to allow the dryer door to

open fully.

Additional spacing should be considered for ease of

installation and servicing.

Additional clearances might be required for wall, door and

floor moldings.

Additional spacing should be considered on all sides of the

1"

27"

1"

(2.5 cm)

(68.6 cm)

(2.5 cm)

 

A

 

 

3"*

 

(7.6 cm)

48 in.2*

 

(310 cm2)

 

24 in.2*

3"*

(155 cm2)

 

(7.6 cm)

 

1"

33"

 

 

5"

 

(2.5 cm)

(83.8 cm) (12.7 cm)

BC

dryer to reduce noise transfer.

Companion appliance spacing should also be considered.

NOTE: This dryer cannot be stacked on the washer.

A. Front view

B. Side view - closet or confined area

C. Closet door with vents

*Required spacing

5

Page 5