![](/images/new-backgrounds/1063287/6328739x1.webp)
PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine, Taste and Odor, Particulate Class I*; and against ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene,
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction | NSF | Average | Influent Challenge | Maximum | Average | Minimum % | Average % | NSF Test |
Aesthetic Effects | Reduction | Influent | Concentration | Effluent | Effluent | Reduction | Reduction | Number |
| Requirements |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Chlorine Taste/Odor | ≥50% | 2.1 mg/L | 2.0 mg/L ± 10% | 0.06 mg/L | 0.05 mg/L | 97.1% | 97.6% | |
Particulate Class 1* | ≥85% | 5,366,667/mL | At least 10,000 | 4,100/mL** | 2,300/mL | 99.3% | 99.9% | |
|
|
| particles/mL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contaminant | NSF | Average | Influent Challenge | Maximum | Average | Minimum % | Average % | NSF Test |
Reduction | Reduction | Influent | Concentration | Effluent | Effluent | Reduction | Reduction | Number |
| Requirements |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.01mg/L | 0.16 mg/L*** | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.3% | 99.35% | |
Lead: @ pH 8.5 | 0.01mg/L | 0.15 mg/L*** | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.2% | 99.31% | |
|
|
|
|
|
|
|
|
|
Mercury: @ pH 6.5 | 0.002 mg/L | 0.0061 mg/L | 0.006 mg/L ± 10% | 0.0004 mg/L | 0.0003 mg/L | 93.5% | 96.7% | |
Mercury: @ pH 8.5 | 0.002 mg/L | 0.0057 mg/L | 0.006 mg/L ± 10% | 0.0008 mg/L | 0.00051 mg/L | 85.8% | 91.2% | |
|
|
|
|
|
|
|
|
|
Benzene | 0.005 mg/L | 0.0138 mg/L | 0.015 ± 10% | 0.0005 mg/L | 0.005 mg/L | 96.3% | 96.3% | |
|
|
|
|
|
|
|
|
|
0.075 mg/L | 0.220 mg/L | 0.225 ± 10% | 0.0005 mg/L | 0.0005 mg/L | 99.7% | 99.7% | ||
|
|
|
|
|
|
|
|
|
Toxaphene | 0.003 mg/L | 0.014 mg/L | 0.015 ± 10% | 0.0014 mg/L | 0.001 mg/L | 90% | 92.96% | |
|
|
|
|
|
|
|
|
|
Atrazine | 0.003 mg/L | 0.009 mg/L | 0.009 mg/L ± 10% | 0.0013 mg/L | 0.00036 mg/L | 85.6% | 85.6% | |
|
|
|
|
|
|
|
|
|
2, | 0.07 mg/L | 0.197 mg/L | 0.215 ± 10% | 0.058 mg/L | 0.0137 mg/L | 70.6% | 93.06% | |
|
|
|
|
|
|
|
|
|
Asbestos | 99% | 26 x 107 | 107 to 108 fibers/L**** | 0.18 x 107 mg/L | 0.18 x 107 mg/L | 99.93 | 99.93% | |
|
|
|
|
|
|
|
|
|
Cysts***** | 99.95% | 111,000/mL | 50,000/L min. | 1 mg/L | 1 mg/L | 99.99% | 99.99% | |
Turbidity | 0.5 NTU | 11.08 NTU | 11 ± 1 NTU | 0.13 NTU | 0.078 NTU | 98.8% | 99.3% | |
|
|
|
|
|
|
|
|
|
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Model
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
■Refer to the front cover or “Accessories” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8° C) |
Service Flow Rate | 0.5 GPM (1.89 L/min.) @ 60 psi. |
|
|
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
****Fibers greater than 10 um in length
*****Based on the use of Cryptosporidium parvum oocysts
®NSF is a registered trademark of NSF International.
20