PERFORMANCE DATA SHEETS

Base Grille Water Filtration System

Model T1WB2L/T1RFWB2 Capacity 200 Gallons (758 Liters)

Model T1WB2/T1RFWB2 Capacity 200 Gallons (758 Liters)

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane, Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene and Ethylbenzene.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50% reduction

2.0 mg/L

2.0 mg/L ± 10%

0.08 mg/L

2.0 mg/L

95.93

97.36

Particulate Class I*

85% reduction

3533333#/mL

At least 10,000

22000 #/mL**

11567 #/mL

99.38

99.67

 

 

 

particles/mL

 

 

 

 

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.010 mg/L

150 ug/L

0.15 mg/L ± 10%

1.0 ug/L

1 ug/L

99.33

99.33

Lead: @ pH 8.5

0.010 mg/L

157 ug/L

0.15 mg/L ± 10%

2.0 ug/L

1.08 ug/L

98.72

99.31

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.0058 mg/L

0.006 mg/L ± 10%

0.0002 mg/L

0.0002 mg/L

96.53

96.53

Mercury: @ pH 8.5

0.002 mg/L

0.0057 mg/L

0.006 mg/L ± 10%

0.0002 mg/L

0.0002 mg/L

96.5

96.5

 

 

 

 

 

 

 

 

Benzene

0.005 mg/L

15 ug/L

0.015 mg/L ± 10%

0.5 ug/L

0.5 ug/L

96.67

96.67

 

 

 

 

 

 

 

 

O-Dichlorobenzene

0.6 mg/L

1750 ug/L

1.8 ± 10%

1.0 ug/L

1.0 ug/L

99.94

99.94

 

 

 

 

 

 

 

 

Toxaphene

0.003 mg/L

15 ug/L

0.015 ± 10%

1.0 ug/L

1.0 ug/L

93.33

93.33

 

 

 

 

 

 

 

 

Atrazine

0.003 mg/L

10 ug/L

0.009 mg/L ± 10%

2 ug/L

2 ug/L

80.8

80.8

 

 

 

 

 

 

 

 

Asbestos

99%

101 MFL

107 to 108 fibers/L††

0.17 MFL

0.17 MFL

99.83

99.83

 

 

 

 

 

 

 

 

Live Cysts

>99.95%

120,000/L

50,000/L min.

8/L

1/L

99.99

>99.99

Turbidity

0.5 NTU

11.4 NTU

11 ± 1 NTU

0.41 NTU

0.24 NTU

96.4

97.89

 

 

 

 

 

 

 

 

Alachlor

0.002 mg/L

41.3 ug/L

0.04 ± 10%

0.2 ug/L

0.2 ug/L

99.52

99.52

 

 

 

 

 

 

 

 

Endrin

0.002 mg/L

5.9 ug/L

0.006 ± 10%

0.5 ug/L

0.3 ug/L

91.5

95.47

 

 

 

 

 

 

 

 

Ethylbenzene

0.7 mg/L

1867 ug/L

2.1 ± 10%

0.70 ug/L

0.0588 ug/L

99.96

100

 

 

 

 

 

 

 

 

Lindane

0.002 mg/L

1.9 ug/L

0.002 ± 10%

0.02 ug/L

0.02 ug/L

98.93

98.93

 

 

 

 

 

 

 

 

Chlorobenzene

0.6 mg/L

2.0 ug/L

2.0 ± 10%

0.0005 ug/L

0.0005 ug/L

99.98

99.98

 

 

 

 

 

 

 

 

Tetrachloroethylene

0.005 mg/L

14.2 ug/L

0.015 ± 10%

0.5 ug/L

0.5 ug/L

96.47

96.47

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Use replacement cartridge T1RFWB2, part #4396711.

2007 suggested retail price of $39.99 U.S.A./$49.99 Canada. Prices are subject to change without notice.

Model T1WB2L: Style 1 – When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Refer to the back cover or “Accessories” section for the Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Style 2 – When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter.

Model T1WB2: Change the water filter cartridge every 6 months depending upon your usage. If the water flow to the water dispenser or ice maker decreases noticeably before 6 months have passed, replace the water filter cartridge more often.

These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.

The product is for cold water use only.

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. ††Fibers greater than 10 um in length

Based on the use of Cryptosporidium parvum oocysts ® NSF is a registered trademark of NSF International.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8°C)

Service Flow Rate

0.5 gpm (1.9 L/min.) @ 60 psi.

10

Page 10
Image 10
KitchenAid W10162434A warranty Performance Data Sheets, Application Guidelines/Water Supply Parameters