Installation:

The PRM200 power source connection must be adequate for use at 20 amps. We recommend a properly grounded 30-amp circuit, wired with 10-gauge wiring, if continuous operation near 20 amps is anticipated. A dedicated (nothing else connected) 20-amp circuit is the minimum acceptable to comply with NEC requirements. Consult a qualified electrician if in doubt.

Please note the PRM200 cord plug requires a different style outlet than a conventional style 15-amp outlet.

CABLE TV INPUT

CONNECT CABLE

BEFORE ANY TV’S

3-24vdc TRIGGER ON OR VCR’S ETC. VIA 3.5 mm MONO JACK

120 VAC

DELAY MAX

DELAY MED

DELAY MIN

UNSWITCHED

SAT DISH INPUT CONNECT TO SAT DISH

120VAC Input

THESE TW O OUTLETS

TURN ON 4 SECO NDS

PRM150

A FTER POW ER UP AND

TURN OFF

MAX 15 AMPS

IM MEDIATELY AFTER

 

POW ER DOW N. AMPS

PRM200

A ND SUBSARE

CONNECTED HERE

MAX 20 AMPS

 

THESE TWO OUTLETS TURN ON 2 SECONDS AFTER POWER UP AND TURN OFF 2 SECONDS AFTER POWER DOWN. AMPS AND DVD’S ARE CONNECTED HERE

THESE TWO OUTLETS TURN ON IMMEDIATELY AT POWER UP AND ARE THE LAST TO TURN OFF AT POWER DOWN.

AUDIO PROCESSORS, CD AND VIDEO ARE CONNECTED HERE

THESE TWO OUTLETS ARE ON ALL THE TIM E. VCR, CLOCK S AND STANDBY EQUIPM ENT ARE CONNECTED HERE

CABLE TV OUTPUT

CONNECT TO TV’S

VCR’S, SPLITTERS

ETC. IN HOME.

SAT DISH OUTPUT

CONNECT TO SAT

DISH RECEIVER

TELEPHONE INPUT AND OUTPUT. CONNECT EITHER JACK TO THE TELEPHONE LINE BEFORE ANY TELEPHONE OR MODEM IN THE HOME, THEN CONNECT THE OTHER JACK TO HOME EQUIPMENT. ONLY THE CENTER PAIR IS ACTIVE

The PRM150 requires a dedicated properly grounded 15-amp circuit to operate at capacity. We suggest that a dedicated 15-amp breaker be installed at the breaker box for use with the PRM150.

It is best if the PRM150 or PRM200 is located with other equipment so that extension cords are not required. Heat is not a consideration when placing the power conditioner.

Plug all the AC power cords from all components directly into the back of the power conditioner. This offers full line conditioning and filtering for your entire system.

Keep in mind that Knoll power conditioners can only do so much in the cases of lightning strikes and large surges. If your area is prone to lightning strikes and large surges we strongly suggest you have a whole house lightning arrestor installed. Ask you power provider for more information.

The un-switched outlets are for components that require full time power such as VCR’s or TV’s. If you wish to turn on your system via an existing component with remote control access (such as a receiver with a switched ac outlet on the back), plug your receiver into the un-switched outlet on the power conditioner (and read the section below on rear panel trigger).

Page 3
Image 3
Knoll Systems PRM150, PRM200 installation instructions Installation

PRM150, PRM200 specifications

Knoll Systems has gained recognition in the realm of professional audio equipment with its innovative line of remote control and monitoring solutions, particularly the PRM200 and PRM150 models. These remote monitoring devices are designed to provide reliable and efficient control for a variety of audio applications.

The PRM200 is a robust remote control solution that features an intuitive user interface, allowing operators to manage multiple audio sources seamlessly. One of its standout features is the dual-channel audio monitoring, which enables users to listen and switch between two inputs simultaneously. This capability is essential for audio engineers and operators who need to ensure that both channels are being monitored effectively during live performances or studio recordings.

On the other hand, the PRM150 offers a more compact option without compromising on functionality. This device is designed for streamlined setups and is ideal for users who need a reliable control solution without the extensive feature set of the PRM200. The PRM150 includes essential monitoring capabilities, supporting single-channel audio and providing clear visual indicators for signal status, making it user-friendly and efficient for smaller scale operations.

Both models utilize advanced technologies, such as high-quality digital signal processing and low-latency transmission, ensuring that audio signals remain clear and distortion-free. This emphasis on audio fidelity is crucial for professional applications where sound quality is a top priority. Moreover, both the PRM200 and PRM150 demonstrate Knoll Systems' commitment to durability and reliability, featuring rugged designs that can withstand the demands of live environments.

Connectivity options are another essential aspect of these devices. The PRM200 and PRM150 support various input and output formats, including analog and digital connections, making them versatile for integration with different audio systems. This adaptability allows audio professionals to implement the devices in various setups, whether in studios, broadcasting stations, or on stage.

In summary, Knoll Systems' PRM200 and PRM150 remote monitoring devices exemplify the brand's dedication to delivering high-quality audio control solutions. With their array of features, advanced technologies, and user-friendly designs, these models cater to a wide range of audio professionals, enhancing their ability to produce exceptional audio experiences.