INSTALLATION

INSTALLATION

PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING

Calculation before Installation

To calculate installation, please refer to Table 1. (All calculation in inches.)

TABLE 1

A = Height of Floor to Ceiling

B = Height of Floor to Counter Top (Standard: 36”)

C = Preferred Height of Counter Top to Hood

Bottom (Recommended 27” to 30”)

D = Height of Hood

E = Height of Duct Cover [F – D]

F = Height of Hood Installation

[A – (B + C)]

Calculation before InstallationSAFETY WARNING

HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.

Preparation before Installation

NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING.

-Decide the location of venting pipe from the hood to the outside. Refer to Figure 1.

-A straight, short venting run will allow the hood to perform more efficiently.

-Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.

-Use duct tape to seal the joints between pipe sections.

-Temporarily wire the hood to test for proper operation before installing.

1.If necessary, prepare back wall frame with cross

framing lumber for secure installation. Using references in Table 1 and measurements on page 12, decide the level of the lumber. Refer to Figure 2.

Figure 1

Figure 2

4