6.Align hood to the hood-mounting bracket on the wall and hook hood into place a on Figure 6 & 7. CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE

RELEASING.

Figure 6 Figure 7

7.For safety purposes, install the safetywithbracketonescrews (not provided) to the wall as shown on Figure 8.

Ductwork Installation

8.Use 7￿ round aluminum or steel pipe to connect the plastic damper on the hood ductwork above.

9.Use duct tape to make all joints secure and air tight. Make sure pipe is conn between the gaps of the plastic damper. Refer to Figure 9.

Figure 8

Figu

Wiring to Power Supply

SAFETY WARNING

RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.

10.Connect three wires (black, white and green) to house wires and cap with wire connectors.

11.Connect according to color: black to black, white to white, and green to gre

6

Page 8
Image 8
Kobe Range Hoods CX1836GS installation instructions Releasing, Wiring to Power Supply