Ductwork Installation
Figure 8
Figure 7

4.Secure and tighten the mounting screwsFigure. 5

CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING.

Ductwork Installation

5. Using ReferenceE from Table 1 and measurements on Page11, mark the leveling point for duct cover-mounting bracket.

6. Secure the duct cover-mounting bracket to the wall with two screws (not provided). (Figure 6) Make sure all screws are

tightened. NOTE: Inner duct cover will Figure 6

cover the duct cover-mounting bracket.

7.Use aluminum or steel pipe (not provided) to connect the plastic exhaust on the hood to the ductwork above. Use duct tape to ensure all joints are secure and air tight as shown in Figure 7.

Wiring to Power Supply

Wiring to Power SupplySAFETY WARNING

RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY A SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.

.

8.Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green

to green as shown in Figure 8

9.Test the operation of the hood before performing the next step. Make sure power is supplied to the hood.

Duct Cover Installation

10.Slide inner duct cover up 2 inches before sliding entire duct cover onto the hood. (Figure 9)

11.Align the inner duct cover to the duct cover-mounting bracket. Secure