Instructions for Kodak i200 Series Scanners

Instructions for Kodak i200 Series Scanners

1.Power down the scanner.

2.Access the inside of the scanner by opening the scanner cover.

3.Lift up the scanner door release again and open the scanner door past the circuit board cover.

Upper imaging guide

Circuit board cover

Lower imaging guide

Replacing the Upper Imaging Guide

1.Locate the upper imaging guide.

2.Clean the upper transport area and imaging guide.

3.Remove the screw from the upper imaging guide bracket.

Upper imaging guide

Screw

Bracket

4.Slide the bracket away from the imaging guide.

5.Pull gently on the end of the imaging guide and slowly remove it from the scanner.

6.Discard the used imaging guide.

7.Remove any dust or debris from the guide track. Do not allow debris to fall into the scanner.

8.Wipe both sides of the new upper imaging guide with a fresh Staticide Wipe.

9.Dry both sides of the new upper imaging guide with a dry Staticide Wipe.

10.Align the new upper imaging guide in the guide track and slowly push it in.

11.Slide the bracket until it rests against the end of the imaging guide.

12.Re-install the screw in the upper imaging guide bracket. Do not over-tighten.

Replacing the Lower Imaging Guide

1.Locate the lower imaging guide.

2.Clean the lower transport area and imaging guide.

3.Remove the screw from the lower imaging guide.

Screw

Lower imaging guide

4.Pull gently on the end of the imaging guide and slowly remove it from the scanner.

5.Discard the used imaging guide.

6.Remove any dust or debris from the guide track. Do not allow debris to fall into the scanner.

7.Wipe both sides of the new lower imaging guide with a fresh Staticide Wipe.

8.Dry both sides of the new lower imaging guide with a dry Staticide Wipe.

9.Align the new lower imaging guide in the guide track and slowly push it in.

10.Re-install the screw in the lower imaging guide. Do not over-tighten.

11.Close the scanner door.