Processing Options
M100 Film can be processed manually or automatically in a range
of processing cycles.
KODAK INDUSTREX M100 Film
Exposure:
220 kV Direct X-rays with lead screens
Processing:
KODAK INDUSTREX Processor
KODAK INDUSTREX Chemicals
Densitometry:
Di use Visual
Notice: Observe precautionary information on product labels and Material Safety Data Sheets. Develop with rack
and tank, using properly replenished solutions.
1Contrast calculated between net densities of 1.5 and 3.5.
For More Information
To learn more about KODAK INDUSTREX M100 Film and other
Carestream Health NDT products and solutions, contact a
Carestream Health representative at 877-865-6325 ext 714 or
visit www.carestreamhealth.com/go/ndt.
KODAK INDUSTREX
Processors/Cycles
M43IC—8 min 79°F (26°C)
M43IC—5 min 86°F (30°C)
Base + Fog
0.19
0.19
Contrast1
5.4
5.25
Developer
KODAK INDUSTREX
Single Part Developer
Replenisher
Temperature
68˚F (20˚C)
72˚F (22˚C)
75˚F (24˚C)
79˚F (26˚C)
Agitation
Intermittent
(5 seconds,
every 30 seconds)
Recommended
Time (Mintes)
5
4
3
2
Carestream Health, Inc. Rochester, N.Y. 14608
© Carestream Health, Inc. 2007. Kodak and the
Kodak trade dress are trademarks of Kodak used
under license.
CAT 137 5617
Exposure:
220 kV Direct X-rays with lead screens
Processing:
Manual; KODAK INDUSTREX Single Part
Developer Replenisher
Densitometry:
Di use Visual
Automatic Processing
See Carestream Health publication TI-2621, Processing
KODAK INDUSTREX Films, for additional information on
automatic processing.
Manual Processing
See Carestream Health publication TI-2643, Guide to Manual Pro-
cessing of KODAK INDUSTREX Films, for additional information on
manual processing.
Develop with rack and tank, using properly replenished solutions.
Film Characteristics (Sensitometric)
ISO/EN exposure conditions: 200/220 kV, lead screens; KODAK INDUSTREX Single Part Developer
Replenisher and KODAK INDUSTREX LO Fixer and Replenisher.
Exclusive manufacturer of Kodak INDUSTREX Products