Install the Finished Wall
Cutout
1.Finish the wall, leaving the cutout 102 to 108 mm square.
2.Make sure that the dimension from the front face of the elbow or tee to the surface of the finished wall is a minimum of 57 mm.
3.Thread the nipple into the elbow or tee and hand tighten.
4.Measure the distance from the end of the nipple to the surface of the finished wall. Make sure that it is between 38 and 44 mm. If necessary cut the nipple to the required length.
5.Remove the nipple and apply thread sealant to the ends of the nipple.
6.Reinstall the nipple to the elbow or tee.
7.Turn obn the water supply and flush out the supply pipes.
Install the Waterway
102 to 108 mm
Tee (or Elbow)
57 mm Min
102 to 108 mm
Finished Wall
Cutout
Nipple
102 to 108 mm
1.Install the concealing plate into the
rough opening. The double ribs of the
leak shield should be facing up.
2.If the leak shield makes contact with the elbow enlarge the hole in the back of the leak shield to 32 mm.
3.Thread the adapter onto the nipple using a 7/16” hexagonal wrench.
Important! be careful not to damage the flow adapter. The concealing plate should fit loosely at this point.
4.Align the groove in the waterway with the double ribs on the leak shield.
5.Press the waterway into place over the adapter.
6.Secure the waterway to the adapter with the screw provided.
7.Make sure that the concealing plate does not turn and is not loose.
Important! If the concealing plate is still loose at this point shorten the nipple.
Concealing Plate
Leak Shield
Waterway
Adapter 7/16" Hex Wrench Screw