3.Install the adapter onto one of the nipples using the 11 mm bit (supplied), 11 mm or 7/16” socket, the extension and the socket wrench.
Note! Use masking tape to hold the bit in place, as the bit could fall off and cause damage.
Important! The concealing plate should sit loosely at this point. If it is tight against the ceiling, use a longer pipe nipple.
4.Align the groove in the waterway with the double ribs on the leak shield.
5.Press the waterway into place over the adapter. Secure the waterway to the adapter with the screw.
6.Make sure that the concealing plate does not turn or move.
Important! If the concealing plate is still loose after this step, then use a shorter pipe nipple.
7.Repeat the procedure for the remaining waterways.
Install the Trim
Ribs
Groove
Waterway
Sprayhead
Hex Screws
Nozzle Membrane
Install the Sprayhead
1.With the ribs of the sprayhead facing upwards, attach the sprayhead to the waterway.
2.Using a 3/16” hexagonal wrench, install the hexagonal screws to secure the sprayhead in position. Do not overtighten.
3.Check the sprayhead for upward and downward movement and make sure that it sits squarely within the concealing plate.
4.Place the nozzle membrane over the sprayhead.
5.Align the long edge of the membrane with the hinge ribs (horizontal).
Note! For optimum performance, make sure that the membrane is applied evenly.
7 |