Troubleshooting (cont.)

Effervescent Ports

Symptoms

Probable Causes

Recommended Action

1. Effervescent ports do not

A.

Whirlpool pump is not

A.

Turn on pump.

work.

 

operating.

 

 

 

B.

Butterfly valve does not work.

B.

Replace butterfly valve.

 

C.

Pump does not work.

C.

Refer to the service manual to

 

 

 

 

troubleshoot the system. Refer to

 

 

 

 

installer/dealer.

 

D. Control does not work.

D. Replace control.

2. Effervescent ports do not

A.

Air intake on suction line is

A.

Remove blockage.

bubble.

 

blocked.

 

 

 

B.

Water flow is too low.

B.

Increase water flow.

 

 

 

 

 

Chromatherapy Lights

 

 

 

 

Symptoms

Probable Causes

Recommended Action

1. Chromatherapy lights do

A.

Loose, disconnected or damaged

A.

Check wiring for proper

not work.

 

wiring/connections.

 

connections. Replace wiring if

 

 

 

 

necessary.

 

B.

Control does not work.

B.

Replace control.

 

 

 

 

 

Remote Control

 

 

 

 

Symptoms

Probable Causes

Recommended Action

1. Remote control does not

A.

Batteries improperly installed or

A.

Replace batteries.

work.

 

dead.

 

 

 

B.

Antenna on wiring harness is

B.

Replace wiring harness.

 

 

damaged.

 

 

 

C.

Remote control not programmed

C. See homeowners guide or service

 

 

correctly.

 

manual.

 

D. Remote control does not work.

D. Replace remote control.

 

E.

Control does not work.

E.

Replace control.

 

 

 

 

 

1023246-5-C

12

Kohler Co.

Page 12
Image 12
Kohler K-1418-CT manual Remote Control Symptoms Probable Causes Recommended Action