9

5

9

5

4

4

8

3

8

3

7

2

7

2

6

1

6

1

 

 

Figure 4: Crossed Cable RS-232 Connection

PC

Hardware flow control is not required for this unit. In the rare case where a controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 on the controller side.

Method B (Figure 5)—Connect the RS-232 9-pin D-sub port on the unit via a straight (flat) cable to the null-modem adapter, and connect the null-modem adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually contains all nine wires for a full connection of the D-sub connector. Because the null-modem adapter (which already includes the flow control jumpering described in Method A above) only requires pins 2, 3 and 5 to be connected, you are free to decide whether to connect only these 3 pins or all 9 pins.

9

5

4

8

3

7

2

6

1

 

Null-Modem

Adapter

to PC

Figure 5: Straight Cable RS-232 Connection with a Null Modem Adapter

VA-4 - Connecting the VA-4

9

Page 12
Image 12
Kramer Electronics VA-4 user manual To PC