KRAMER: SIMPLE CREATIVE TECHNOLOGY

Configuring and Controlling the VP-725xl

20

8.1.1 The Input Screen

Figure 9 and Table 5 define the Input screen.

Figure 9: Input Screen

Table 5: Input Screen Functions

Setting Function Selection/Range Default
Select Select the group Video Group, Scaler Scaler
VGA Group Select the VGA input1 From 1 to 4 VGA 1
HDMI Group Select the HDMI input
1
From 1 to 4 HDMI 1
Comp Group Select the Comp input1 From 1 to 4 Comp 1
YC Group Select the YC input
1
From 1 to 4 YC 1
CV Group Select the CV input
1
From 1 to 4 CV 1
Scaler Select the source to scale
(in the Scaler operation
mode)
From VGA 1 to VGA 4; from HDMI 1 to HDMI 4;
from COMP 1 to COMP 4; from YC 1 to YC 4;
from CV 1 to CV 4, and USB
VGA 1
Image Name Shows the file name
2
that is displayed when the USB port is connected
Color Format Select the color format Auto, RGB or YUV Auto
Video
Standard
Select the video standard Auto, NTSC, PAL, PAL-M, PAL-N, NTSC 4.43,
SECAM or PAL-60
H-Position Set the horizontal position3 The range changes according to t he input mode Auto
V-Position Set the vertical position The range changes according to t he input mode
Frequency Adjust the frequency
4
The range changes according to the input mode
Phase Adjust the phase 0 to 31 0
Auto image Assesses the image and improves the quality acc ordingly, by automatically
adjusting the phase, frequency and position. Upon completion, the relevant
OSD values are updated (Hpos, Vpos, Phase and Frequency)
1 In the Video Group operation mode
2 Supports JPEG format only. The JPEG file should not exceed a resolution of 2048x1536. If the image file is not within the
definition a blank screen appears and the machine displays the message: "File too big" or "File too small" (smaller than
320x240)
3 For UXGA and component video inputs
4 For UXGA inputs