KRAMER Electronics, Ltd. 10
For example, to connect input 4 to output 2, N12N11N10N9N8 should be set up as 01110 (=14). To
connect input 3 to all the outputs, set N12N11N10N9N8 = 11011 (=27). To disconnect output 1, set
N12N11N10N9N8 = 11010 (=26). Similarly, if the front panel switches were pressed to connect input
2 to output 3, then N12N11N10N9N8 would be transmitted as 00111 (=7).