Wiring the U.K. and European TP Terminal Blocks
The European wall plates are equipped with an easy
Figure 4 defines the pinouts for the TP terminal block.
Figure 4:
Notes:
•Use the connector clips when removing the wires, not when inserting them
•Each wire protrudes 9mm in length from the plastic insulation so that it can be easily connected. To prevent the wires crossing, be sure that each wire is completely inserted
•The cable ground shielding must be connected / soldered to the connector shield
Grounding the Wall Plate
Use the grounding screw to earth the chassis of the unit to the ground of the building. This prevents static electricity from interfering with the product’s performance.
Figure 5 defines the grounding screw components.
# | Item |
1 | M3X6 screw |
2 | 1/8" Toothed Lock Washer |
3 | M3 Ring Tongue Terminal |
Figure 5: Grounding Screw Components
To ground the wall plate:
1.Connect the ring tongue terminal to the building grounding point wire. We recommend using a
2.Insert the M3x6 screw through the toothed lock washers and the tongue terminal in the order shown above.
3.Insert the M3x6 screw (through the two toothed lock washers and ring tongue terminal) into the grounding screw hole and tighten the screw.
WP-306
Wall Plate
Installation Instructions