System Controls
ON
OFF
Volume
The input sensitivity is adjusted (counte rc loc kwis e red uce s sensitivity) with the rear panel
mounted Volume control. Adjustment range is from
need to adjust this to match the level of your monitors.
L o w-P as s Fr equ ency
Adjustment
using the Subwoofer Line Outs for the monitors, you will want to place this at the 80Hz position (see additional information in the Installing Your Monitors section).
Phase Switch
Functionally, the Phase switch is a polarity inversion mechanism whose position affects the phase relation of the subwoofer output to the other speakers in your room. The proper switch position of 0 or 180 degrees depends on a number of variables. These variables include, the distance of the subwoofer from the listening position and monitors, as well as the
system's absolute polarity and the bass response of the room (refer to the Subwoofer Setup and Placement section in order to determine the correct switch position for your monitoring system and room).
Using the Ground Lift
Engaging the ground lift switch can sometimes reduce ground loop noise in your system. By providing an AC mains ground on the KRK10s and proper installation in a 'quiet studio' environment, the system is happily quiet. However, noise will be induced if the monitor is installed in less than desirable settings (i.e. audio cables run alongside power cables, behind
refrigerators, near florescent lighting, older buildings with bad wiring), or with certain equipment with lots of RFI
The Ground lift switch does not affect the AC mains/panel safety ground. It does not 'open' the connection thru
5