Connecting Your System
IMPORTANT: All connections should be made, all fader and controls should be set at their minimum levels, and all other equipment should be powered prior to powering up your RoKit G2 monitors.
NOTE: Ensure that the voltage indicator found in the voltage selector is set to the correct voltage setting for your local supply.
Powering On
The power On/Off switch is located on the rear panel. The KRK logo on the front face plate illuminates when power is applied.
Changing Voltage
To change the voltage, remove the power cord and slide the voltage selector to the desired voltage setting. Please note that when making voltage changes, the fuses will have to be replaced (refer to the Changing Fuses section below).
Changing Fuses
Under normal operation the fuses should not blow. A blown fuse usually indicates an overload or fault condition. To change the fuse, remove the power cord, pry off the fuse block with a small flathead screwdriver and change the blown fuses. Refer to the Specifications section for fuse current ratings.
NOTE: If the fuses blow immediately upon power up, this indicates a fault condition and the monitor should be returned to KRK for repair.
Audio Inputs
The XLR and TRS inputs are balanced while the RCA input is unbalanced.
Unbalanced
Balanced
Audio Input 10kohms Balanced Pin 2 + Tip = High Pin 3 + Ring = Low Pin 1 + Sleeve = Ground
8