Kuma Stoves K-400, K-300 manual Section L- Installation Instructions

Models: K-400 K-300

1 12
Download 12 pages 13.19 Kb
Page 8
Image 8

7

Section L- Installation Instructions (continued..)

A stove top connector section may be required with reduced clearances installations (double-wall connector). WARNING: Never pass a chimney connector through an attic or roof space, closet or similar concealed space, or a floor or ceiling. Where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365. DO NOT CONNECT TO ANY AIR DISTRIBUTION OR DUCT SYSTEM.

*Chimney- This room heater must be connected to either an 8” chimney complying with the requirements for Type HT chimneys in the standard for Chimneys, Factory-Built, Residential Type and Building Heating Appliance, UL HT 103, or a code approved masonry chimney with a flue liner. (See figure 5 for list of parts).

*CLEARANCES- Refer to Section ‘O’ figures 2 and 3 for minimum installation clearances to combustibles. NOTE: Clearances may only be reduced by means approved by the regulatory authority.

INSTALLATION INSTRUCTIONS:

1)Set the unit on the floor protector.

2)Make sure the clearance from the unit to combustibles is according to the minimum clearances in figures 2 and 3. Also make sure of the minimum clearances from the chimney connector to combustibles.

3)Check the minimum clearances on the floor protector as per figure 4.

4)Connect the unit to the chimney with the chimney connector (stovepipe) using a slip connector usually supplied in a basic stovepipe kit.

5)Fasten the stove pipe sections together securely with screws, and screw the stovepipe to chimney connection at ceiling or wall.

6)Double check all clearances and connections before operation.

*DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY

SERVING ANOTHER APPLIANCE*

*THIS STOVE IS NOT APPROVED FOR INSTALLATION INTO MOBILE HOMES*

List of Replacement Parts (K-300 or K-400)

KRP-CATS- Catalytics and Gasket

KRP-GLASS1- Glass

KRP-GSKT58- Door Gasket Kit (5’)

KRP-GSKT34- Window Gasket Kit (5’)