Module Characteristics

 

 

 

 

 

Dimensions:

65.43in/51.97in/1.8in

 

Standard Test Conditions (STC)

 

 

 

 

STC = 1000 W/M2 irradiance, 25oC module temperature, AM 1.5 spectrum*

 

length/width/height

(1662mm/1320mm/46mm)

 

 

KD315GX-LPB

KD320GX-LPB

 

 

Weight:

60.6lbs (27.5kg)

 

 

 

 

 

 

 

Pmp

315

320

W

PACKAGING SPECIFICATIONS

 

 

 

 

 

 

Vmp

39.8

40.1

V

Imp

7.92

7.99

A

Voc

49.2

49.5

V

Isc

8.50

8.60

A

Ptolerance

+5/-3

+5/-3

%

Nominal Operating Cell Temperature Conditions (NOCT)

NOCT = 800 W/M2 irradiance, 20oC ambient temperature, AM 1.5 spectrum*

T

45

45

oC

NOCT

 

 

 

Pmax

226

230

W

Vmp

35.8

36.1

V

Imp

6.34

6.40

A

Voc

45.0

45.3

V

Isc

6.88

6.96

A

PTC

276.4

280.9

W

Temperature Coefficients

P

-0.46

-0.45

%/oC

max

 

 

 

V

-0.52

-0.51

%/oC

mp

 

 

 

I

0.0064

0.0065

%/oC

mp

 

 

 

V

-0.36

-0.36

%/oC

oc

 

 

 

I

0.061

0.060

%/oC

sc

 

 

 

Operating

-40 to +90

-40 to +90

%/oC

Temp

 

 

 

System Design

 

 

 

Series Fuse Rating

 

 

15 A

Maximum DC System Voltage (UL)

 

600 V

Hailstone Impact

 

1in (25mm) @ 51mph (23m/s)

Modules per pallet:

 

20

Pallets per 53’ container:

 

22

Pallet box dimensions:

 

66in/53in/47in

length/width/height

 

(1675mm/1330mm/1190mm)

Pallet box weight:

 

1323 lbs (600kg)

 

5.24in

1.8in

 

133mm

46mm

11.06in 281mm

5.36in 136mm

(IP65)

 

40.9in 1040mm

50.8in 1290mm

21.65in 550mm

 

STABILIZER BAR

 

 

65.43in 1662mm

 

 

21.65in 550mm

 

 

STABILIZER BAR

11.06in 281mm

 

51.97in

 

1320mm

0.87in

 

22mm

Weight: 60.6lbs (28.0kg)

 

.47in

 

12mm

 

1.8in 46mm

 

1.18in

Short Side

30mm

 

11.06in 281mm

.41in

 

10.3mm

 

1.8in 46mm

Long Side

1.18in

 

30mm

*Subject to simulator measurement uncertainty of +/- 3%.

KYOCERA reserves the right to modify these specifications without notice.

NEC 2008 Compliant

UL 1703 Listed

Expanded View of Grounding HolesFrame Cross Section Diagrams

WARNING: Read the instruction

 

 

 

 

manual in its entirety prior to

 

MOUNTING HOLES DRAINAGE HOLES

 

GROUND SYMBOL

handling, installing & operat-

 

 

 

ing Kyocera Solar modules.

 

.35in (9mm)

 

.35in (9mm)

 

 

 

 

 

040513

Our Valued Partner

KYOCERA Solar, Inc. 800-223-9580 800-523-2329 fax www.kyocerasolar.com

Page 2
Image 2
Kyocera KD 300-80 P Series KD 300-80P Series, electrical SPECIFICATIONS, Module Characteristics, Packaging Specifications