La Crosse Technology TX60U-IT Battery Installation, Low Battery Indicator, Mounting, Power Supply

Models: TX60U-IT

1 2
Download 2 pages 15.32 Kb
Page 2
Image 2
BATTERY INSTALLATION

BATTERY INSTALLATION

1.Remove the battery cover by sliding the cover down.

2.Observing the correct polarity install 2 AAA, Alkaline batteries. The batteries will fit tightly (to avoid start-up problems make sure they do not spring free).

3.Replace the battery cover by sliding upwards. Be sure battery cover is on securely.

LOW BATTERY INDICATOR

When batteries are low, the low battery indicator show up on the LCD. You will receive an e-mail or cellular notification (if notifications have been configured) when the battery power of the TX60U-IT sensor is low. Change the batteries immediately.

Note: The LED turns ON briefly after changing batteries. However, the LED turns OFF if there is no Weather Direct® Gateway connected. The previously stored information in the TX60U-IT sensor will not be affected or cancelled while you change the batteries.

MOUNTING

THE TX60U-IT TEMPERATURE & HUMIDITY SENSOR

The TX60U-IT sensor can be mounted onto a wall with the use of screws

MOUNTING WITH SCREWS

1.Remove the mounting bracket from the TX60U-IT sensor.

2.Place the mounting bracket over the desired location.

3.Mark the mounting surface with a pencil through the two screw holes of the bracket,.

4.Screw the mounting bracket onto the mounting surface. Ensure that the screws are tight against the bracket.

5.Insert the TX60U-IT sensor into the bracket.

TABLE STANDING AND OTHER MOUNTING OPTIONS With the mounting bracket installed at the bottom

or on the top of the TX60U-IT sensor, the user can place it on any flat surface.

Note:

Before permanently fixing the TX60U-IT sensor wall base, place all units in the desired locations to check that the outdoor temperature & humidity readings are receivable. In event that the signal is not received, relocate the TX60U-IT sensor or move them slightly as this may help the signal reception.

MAINTENANCE AND CARE

Extreme temperatures, vibration, and shock should be avoided to prevent damage to the units.

Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents; they may mark the displays and casings.

Do not submerge the sensor case in water.

Avoid kinking the temperature probe cable.

Immediately remove all low powered batteries to avoid leakage and damage.

Opening the casings invalidates the warranty. Do not try to repair the unit. Contact La Crosse Technology® for repairs.

SPECIFICATIONS

Data measuring range:

The device sensor:

Temperature range:

-40 °F to 140°F with 0.2°F resolution

 

“OFL” displayed if outside this range.

Humidity measuring range:

3% to 99%

Transmission range:

200 feet (60.96 m) in open space

The probe sensor:

 

Temperature range:

-40 °F to 140°F with 0.2°F resolution

 

“OFL” displayed if outside this range, and

 

displayed “nC” if no connection.

Power Supply:

 

Temperature transmitter :

2 x AAA, IEC LR03, 1.5V

Battery life cycle:

Approximately 24 months

Recommended battery type:

Alkaline

Dimensions (H x W x D):

5.23" x 0.76" x 1.44"

WARRANTY INFORMATION

La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship.

This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and only to the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem determination and service procedures. Warranty service can only be performed by a La Crosse Technology, Ltd authorized service center. The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center.

La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or reconditioned parts or products if found to be defective during the limited warranty period specified above. All replaced parts and products become the property of La Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd. Replacement parts and products assume the remaining original warranty, or ninety (90) days, whichever is longer. La Crosse Technology, Ltd will pay all expenses for labor and materials for all repairs covered by this warranty. If necessary repairs are not covered by this warranty, or if a product is examined which is not in need or repair, you will be charged for the repairs or examination. The owner must pay any shipping charges incurred in getting your La Crosse Technology, Ltd product to a La Crosse Technology, Ltd authorized service center. La Crosse Technology, Ltd will pay ground return shipping charges to the owner of the product to a USA address only.

Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with the following specified exceptions: (1) damage caused by accident, unreasonable use or neglect (including the lack of reasonable and necessary maintenance); (2) damage occurring during shipment (claims must be presented to the carrier); (3) damage to, or deterioration of, any accessory or decorative surface; (4) damage resulting from failure to follow instructions contained in your owner’s manual; (5) damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology, Ltd authorized service center; (6) units used for other than home use (7) applications and uses that this product was not intended or (8) the products inability to receive a signal due to any source of interference.. This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances.

LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S REACH.

This warranty gives you specific legal rights. You may also have other rights specific to your State. Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you.

For warranty work, technical support, or information, please contact:

La Crosse Technology, Ltd

2809 Losey Blvd. S.

La Crosse, WI 54601

Phone: 608.782.1610

Fax: 608.796.1020

For online contact / support / e-mail:

www.lacrossetechnology.com/support

For information on other products: sales@lacrossetechnology.com

For online setup and registration:

www.weatherdirect.com

For online product information:

www.weatherdirect.com/tx60

FCC DISCLAIMER

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:

(1)This device may not cause harmful interference.

(2)This device must accept any interference received, including interference that may cause undesired operation.

All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical or chemical procedures without written permission of the publisher.

This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked and corrections made in the next issue. We accept no liability for technical mistakes or printing errors, or their consequences.

All trademarks and patents are acknowledged.

Page 2