1B. Description

The Laars Lite 2 LD heater gets electrical power from an external 120VAC or 240VAC source and provides a dual thermostat Flex-Temp control system for pool/spa combinations or preheat convenience. The Laars Lite 2 LD heater also meets the California, New York, Hawaii, and Oregon state energy requirements for intermittent ignition gas appliances. The Laars Lite 2 LG heater is a self contained standing pilot unit and requires no external power.

The Laars Lite 2 heater is specifically designed for heating swimming pools and spas. Do not use it as a general service water heater. There is a specially designed model of Laars Lite 2 for heating salt water pools. Consult your dealer for the appropriate Waterpik Laars products for these applications.

1C. Warranty

The Laars Lite 2 heater is sold with a limited factory warranty. Details are specified on the back cover of this manual. A copy of the warranty and a warranty registration card are included in the plastic bag shipped with the heater. Fill out and return the warranty registration card.

Make all warranty claims to an authorized Waterpik Laars representative or directly to the factory. Claims must include the heater serial number and model (this information can be found on the rating plate), installation date, and name of the installer. Shipping costs are not included in the warranty cover- age.

Damage caused by improper installation or assembly, or to the heat exchanger by corrosive water, is NOT covered by the Warranty. See Section 3D for maintaining proper pool water chemistry.

NOTE: Keep this manual in a safe place for future reference when inspecting or servicing the heater.

1D. Technical Assistance

Consult Waterpik Laars or your local distributor with any questions or problems involving the specifica- tions, installation, and operation of your Waterpik Laars equipment. An experienced technical support staff is ready to assist in assuring the proper perfor- mance and application of Waterpik Laars products. For technical support call (415) 382-8220 extension 260.

SECTION 2.

Installation Instructions

2A. General Information

Install the Laars Lite 2 heaters, vent caps and drafthoods in accordance with the procedures in this manual, local codes and ordinances, and in accordance with the latest edition of the National Fuel Gas Code, ANSI Z223.1. In Canada, the installation must be in accordance with CAN1-B149.1 or .2 and local codes. The authority having jurisdiction may require that the installation conform to the Standard for Gas-Fired Heaters, ANSI Z21.56. Any changes to the heater, gas controls, gas orifices, wiring, draft diverter, or im- proper installation may void the warranty. If field conditions require change to any of the above, consult the factory.

All gas-fired products require correct installation to assure safe operation. The requirements for pool heaters include the following:

1.Field assembly (if required)

2.Appropriate site location (clearances) and flooring

3.Sufficient combustion and ventilation air

4.Properly sized gas meter and piping

5.Proper electrical wiring (if required)

6.Adequate water flow

This manual provides the information needed to meet these requirements. Review all application and installation procedures completely before continuing the installation.

2B. Field Assembly

The Laars Lite 2 heater is shipped from the factory with the top assembly in the low-profile configuration for outdoor installation in the U.S. In Canada, an outdoor installation requires the addition of a factory approved vent cap. The Laars Lite 2 heater is design certified for indoor installation when equipped with a drafthood, which must be installed without modification.

The Laars Lite 2 heater is also certified for installation in an outdoor shelter in Canada when equipped with a drafthood. An outdoor shelter is an enclosure not normally occupied which does not communicate directly with occupied areas.

Check the rating plate on the heater or the Parts List (Sec. 4) of this manual for the correct Waterpik Laars drafthood or vent cap part number. See instruc- tions supplied with the drafthood or vent cap for installation and attachment. When the drafthood is used, locate the heater so as to be in the same atmo- spheric pressure zone as the combustion air inlet to the heater.

Page 4
Image 4
Laarsen Associates LG, LD operation manual 1B. Description, 1C. Warranty, 1D. Technical Assistance, 2A. General Information

LG, LD specifications

Laarsen Associates is a reputable engineering and consulting firm known for its innovative solutions in the field of energy and environmental management. Among its notable offerings are the LG and LD series of products, designed to optimize energy efficiency and reduce environmental impact in various applications.

The LG series focuses on providing high-performance tools for efficient energy management in commercial settings. These tools are engineered to integrate seamlessly into existing infrastructures, allowing businesses to monitor, control, and optimize their energy consumption effectively. One of the main features of the LG series is its user-friendly interface, which provides real-time data on energy usage, enabling users to make informed decisions quickly. Furthermore, the enhanced connectivity options facilitate remote access, allowing users to manage their systems from anywhere, significantly improving flexibility and response times.

On the other hand, the LD series is tailored for industrial applications, emphasizing durability and robust performance. The LD products are designed to withstand the harshest environments while maintaining consistent efficiency. Their advanced monitoring systems provide detailed insights into energy consumption patterns, allowing for predictive maintenance and reduced operational costs. Key characteristics of the LD series include high reliability, modular design, and adaptive technologies that can be customized to suit specific industrial requirements.

Both series employ cutting-edge technologies to achieve optimal performance. Smart sensors collect real-time data, which is processed using advanced algorithms to deliver actionable insights. These insights can lead to optimized processes, reduced energy wastage, and enhanced sustainability measures. Moreover, the integration of IoT capabilities allows for smarter energy systems that adapt in real time to changing conditions.

Sustainability is at the core of Laarsen Associates’ offerings. Both the LG and LD series are designed with a commitment to reducing carbon footprints and complying with global standards for environmental protection. Their features not only promote energy efficiency but also support clients in achieving their sustainability goals.

In conclusion, Laarsen Associates’ LG and LD series represent the forefront of energy management and environmental solutions. With their combination of user-centric design, advanced technology, and commitment to sustainability, these products pave the way for businesses and industries to navigate modern energy challenges effectively.