Introduction   
2.7 Technical Specifications Table 3 - Technical Specs 
The transceiver used in the NET485 is intended for balanced data transmission and complies with both EIA 
Standards RS-485 and RS-422. It contains a differential line driver and a differential line receiver, and is 
suitable for half-duplex transfer. The input impedance is 19KOhm allowing up to 50 transceivers to be 
connected on the bus. 
 Category  Description 
CPU   DSTni-EX 186 CPU, 256 KB zero wait state SRAM 
2048KB Flash, 16KB Boot ROM, 1024KB SRAM 
Firmware  Upgradeable via TFTP 
Reset Circuit  Reset In is low active. (Software reset only)   
Serial Interface   RS422/485. Baudrate software selectable (300 to 921600)  
Serial Line Formats  7 or 8 data bits,  1-2 Stop bits, Parity: odd, even, none 
Network Interface   RJ45 Ethernet 10Base-T or 100Base-TX (Auto-sensing) 
Compatibility Ethernet: Version 2.0/IEEE 802.3 
Protocols Supported  ARP, UDP, TCP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, Auto IP, SMTP, and 
HTTP 
Power Input  8VDC to 24VDC, approximately 200ma. 
LEDs  10Base-T & 100Base-TX Activity, Full/half duplex. 
Management  Internal web server, SNMP (read only) Serial login, Telnet login 
Security  Password protection, Locking features, optional Rijndael 128-bit encryption 
Internal Web Server  Serves static web pages and Java applets 
Weight    1.7oz 
Material Case: Flame Retardant 
Temperature   Operating range: -40°C to +85°C (-40°F  to 185°F) High performance mode has an 
upper temperature limit of 75°C. 
Relative Humidity  Operating: 5% to 95% non-condensing  
Warranty 1-year limited warranty 
Included Software  Windows™ 98/NT/2000/XP based Device Installer configuration software, Windows™ 
based Comm Port Redirector.  
EMI Compliance  Radiated & conducted emissions - complies with Class B limits of EN 55022:1998 
Direct & Indirect ESD - complies with EN55024:1998 
RF Electromagnetic Field Immunity - complies with EN55024:1998 
Electrical Fast Transient/Burst Immunity - complies with EN55024:1998 
Power Frequency Magnetic Field Immunity - complies with EN55024:1998 
RF Common Mode Conducted Susceptibility - complies with EN55024:1998 
2-6  NET485 User Guide