Chapter 9: Setup Mode: Channel Configuration

 

 

 

If a partial IP address is presented in a command string, it is

 

 

 

interpreted to be the least significant bytes of the IP address and

 

 

 

uses the internally stored remote IP address to provide the most

 

 

 

significant bytes of the IP address. If the IP address entered is

 

 

 

0.0.0.0/0, the device server enters Monitor Mode.

 

 

 

For example, if the remote IP address already configured in the

 

 

 

unit is 129.1.2.3, then an example command string would be

 

 

 

C3/7. (This would connect to 129.1.2.3 and port 7.) You may

 

 

 

also use a different ending for the connection string. For

 

 

 

example, C50.1/23 would connect you to 129.1.50.1 and port 23.

 

 

 

 

 

 

Figure 9-2. Manual Connection Address Example

 

 

 

 

 

Command String

Result if remote IP is 129.1.2.3 and remote port is 1234

 

 

 

 

 

 

 

C121.2.4.5/1

Complete override; connection is started with host 121.2.4.5, port 1

 

 

 

 

 

C5

Connects to 129.1.2.5, port 1234

 

 

 

 

 

C28.10/12

Connects to 129.1.28.10, port 12

 

 

 

 

 

C0.0.0.0/0

Enters Monitor Mode

 

 

 

Autostart (Automatic

 

If you enable Autostart, the unit automatically connects to the

Connection)

 

remote IP address and remote port specified when the firmware

 

 

 

starts.

 

 

 

Hostlist

 

If you enable this option, the device server scrolls through the

 

 

 

hostlist until it connects to a device listed in the hostlist table.

 

 

 

Once it connects, the unit stops trying to connect to any others. If

 

 

 

this connection fails, the unit continues to scroll through the table

 

 

 

until it is able to connect to another IP in the hostlist.

 

 

 

Hostlist supports a minimum of 1 and a maximum of 12 entries.

 

 

 

Each entry contains the IP address and the port number.

 

 

 

The hostlist is disabled for Manual and Modem Modes. The unit

 

 

 

does not accept a data connection from a remote device when

 

 

 

the hostlist option is enabled.

 

 

 

 

 

XPress DR+ User Guide

74

Page 74
Image 74
Lantronix 900-422 manual Autostart Automatic, Connection, Hostlist

900-422 specifications

The Lantronix 900-422 is a robust industrial device used primarily for remote access and management applications. Known for its reliability and versatility, this product caters to a variety of sectors, including telecommunications, manufacturing, and energy management.

One of the standout features of the Lantronix 900-422 is its ability to provide secure remote management capabilities. With built-in support for secure protocols like SSH and SSL, users can confidently access and control devices over the internet while ensuring data integrity and confidentiality. This security is crucial for applications where sensitive information is transmitted.

The device is equipped with a versatile multi-port serial connectivity option. With support for multiple serial communication protocols, including RS-232 and RS-485, the 900-422 can seamlessly interface with various types of industrial equipment and sensors. This adaptability enhances its usability in diverse environments and tasks, from monitoring weather stations to managing industrial machines.

Another significant characteristic of the Lantronix 900-422 is its compact and rugged design, making it suitable for installation in harsh industrial settings. Its durable exterior is resistant to dust and moisture, ensuring that it maintains performance even in challenging conditions.

The device also features an intuitive web-based interface, simplifying configuration and management. With this graphical user interface, users can quickly set up the device, manage settings, and monitor connected devices, all from a centralized location. This ease of use significantly reduces the time and effort needed for system administrators to maintain their networks.

Additionally, the Lantronix 900-422 is equipped with advanced monitoring and diagnostic tools. Users can track performance metrics and receive alerts for potential issues, enabling proactive maintenance and reducing downtime. The combination of real-time monitoring and remote access capabilities allows organizations to streamline their operations and respond swiftly to any anomalies.

Overall, the Lantronix 900-422 stands out as a reliable solution for remote device access and management. Its blend of security, versatility, and user-friendly features ensures that it meets the diverse needs of modern industrial applications, making it an essential tool for any organization looking to enhance operational efficiency and reliability.