7: Network, Serial Line, and Tunnel Settings
EDS Device Servers User Guide 50
Line –
Configuration
Page Settings
Description
Parity Select the parity used by the currently selected serial line.
Choices are:
None (default)
Even
Odd
Data Bits Select the number of data bits used by the currently selected
serial line. Choices are:
7
8 (default)
Stop Bits Select the number of stop bits used by the currently selected
serial line. Choices are:
1 (default)
2
Flow Control Select the flow control method used by the currently selected
serial line. Choices are:
None(default)
Hardware
Software
Xon char Character to use to initiate a flow of data.
When Flow Control is set to Software, specify Xon char. Prefix
a decimal character with \ or a hexadecimal character with 0x, or
provide a single printable character. The default Xon char is
0x11.
Xoff char When Flow Control is set to Software, specify Xoff char. Prefix
a decimal character with \ or a hexadecimal character with 0x, or
provide a single printable character. The default Xoff char is
0x13.