Lathem AT-MSX manual the removable terminal block

Models: AT-MSX

1 7
Download 7 pages 18.15 Kb
Page 5
Image 5
the removable terminal block.

Installation & User’s Guide

2.Pull and disconnect the removable terminal block and connect the remote devices in the RS485 or Dry Sync connecters. (IMPORTANT: RS485 requires proper polarity + to +, - to -.) Once the connections are secure, reconnect

the removable terminal block.

Apply a minimum of 5.0 to 7.0 lb-in torque for tightening field wires into the removable terminal block. Use Cat-3 or Cat-5 Twisted-Pair Wires. Use only Copper Wire.

3.Insert plug from AC power adapter into the Power In port.

4.Plug the power adapter into an 110vAC outlet.

5.The Status LED will flash once every two seconds. When the signal is received, the LED will flash every second and the AT-MSX will set its internal clock.