Problem

Solution

 

 

At both store and head

IDEALLY, the serial ports and software along the entire polling path from ECR or POS station to the

office locations:

head office polling software should be set the same. These include:

 

• any software in the ECR or POS station that permits polling access

 

• the ECR or POS station’s polling serial port

 

• the ST Plus’s serial port

 

• the “Modem” port on the HQ Plus

 

• the serial port on the host PC that is connected to the “Modem” port on the HQ Plus

 

• the polling software on the host PC at the head office

 

 

HQ Basic does not show active HQ Plus to ST Plus connections

At the head office:

Ensure that HQ Basic is properly installed on its host PC. This PC might or might not be the same PC

 

that is hosting the polling software, but if these two applications are sharing one host PC then

 

ensure that the joint host PC has two distinct serial ports, one for each application to use.

 

 

 

Ensure that HQ Basic is configured to address the same serial port that is connected to the

 

“Console” port of the HQ Plus.

 

 

 

Ensure that the serial port that HQ Basic is addressing is connected to the “Console” port of the HQ

 

Plus using a straight-through serial cable.

 

 

HQ Remote Console and HQ Remote Poller initial setup

At the head office and store

Ensure that a working HQ-ST Link setup is already in place before attempting to add an HQ Remote

locations:

Console or HQ Remote Poller to the mix. Polling software at the head office should be able to

 

successfully poll an ECR or POS station at a remote store location, to verify connectivity.

 

 

HQ Remote Console does not show ST Plus connections on the HQ Plus

At the head office location:

Ensure that HQ Basic running at the head office has been configured to permit remote accesses.

 

 

At the location of the HQ

Ensure that HQ Basic is properly installed on the host PC at the remote location. This PC might or

Remote Console:

might not be the same PC that is hosting an HQ Remote Poller, but if these two devices are sharing

 

one host PC then that PC needs two distinct serial ports, one for each device to use.

 

 

 

Ensure that HQ Basic at the remote location is configured to address the same serial port that is

 

connected to the serial port of the HQ Remote Console.

 

 

 

Ensure that the serial port that HQ Basic is addressing is connected to the serial port of the HQ

 

Remote Console using a straight-through serial cable.

 

 

 

Ensure power is supplied to the HQ Remote Console.

 

 

 

Check that the LAN to which the HQ Remote Console is connected has access to the Internet.

 

 

 

Check that the HQ Remote Console is connected to the LAN with a Cat 5 UTP cable, with an RJ-45

 

connector.

 

 

HQ Remote Poller does not poll the ECR/POS station

At the head office location:

Ensure that HQ Basic running at the head office has been configured to permit remote accesses.

 

 

At the location of the HQ

Ensure that the polling software is properly installed on the host PC at the remote location. This PC

Remote Poller:

might or might not be the same PC that is hosting an HQ Remote Console, but if these two devices

 

are sharing one host PC then that PC needs two distinct serial ports, one for each device to use.

 

 

 

Ensure that the polling software at the remote location is configured to address the same serial port

 

that is connected to the serial port of the ECR/POS station.

 

 

 

Ensure that the serial port that the polling software is addressing is connected to the serial port of

 

the HQ Remote Poller using a straight-through serial cable.

 

 

 

Ensure power is supplied to the HQ Remote Poller.

 

 

 

Check that the LAN to which the HQ Remote Poller is connected has access to the Internet.

 

 

 

Check that the HQ Remote Poller is connected to the LAN with a Cat 5 UTP cable, with an RJ-45

 

connector.

 

 

NOTE: An operating HQ Remote Poller setup is in fact an exercise of most aspects of the HQ-ST Link system. This is because a poll directed from an HQ Remote Poller must successfully pass from the location of the HQ Remote Poller, over the Internet to the HQ Plus running at the head office, out to the Internet again and over to the ST Plus at its store location, through to the ECR or POS station being polled, then back to the ST Plus again and out to the Internet again and over to the HQ Plus, then out to the Internet yet again and back to the HQ Remote Poller, then finally to the remote host PC . This will only happen when all aspects of the full HQ-ST system are working (with the exception of the HQ Remote Console).

Rev. A00

HQ-ST System Manual

Page 29 of 32

Page 31
Image 31
Lava Computer HQ-ST Link system manual HQ Basic does not show active HQ Plus to ST Plus connections

HQ-ST Link specifications

Lava Computer's HQ-ST Link is a robust tool designed for software developers and engineers dedicated to programming and debugging embedded systems. This versatile device combines advanced features with user-friendly technology, making it an indispensable asset for anyone working in the field of embedded software development.

One of the standout features of the HQ-ST Link is its compatibility with multiple microcontroller families, including STM32 and STM8 series. This broad compatibility ensures that developers can utilize the tool across various projects without the need for multiple programming solutions. The tool supports a wide range of communication protocols, making it versatile for various applications.

The HQ-ST Link is equipped with USB 2.0 connectivity, allowing for fast data transfer rates and seamless integration with various development environments. This facilitated connectivity is vital for loading firmware quickly during debugging sessions, ensuring efficiency when developing complex applications.

Additionally, the device supports SWD (Serial Wire Debug) and JTAG (Joint Test Action Group) interfaces, providing flexibility for software developers working with different debugging tools and strategies. The support for these interfaces enables users to conduct in-depth debugging and analysis, leading to efficient debugging processes.

Another noteworthy characteristic of the HQ-ST Link is its built-in programming and debugging capabilities. With advanced features such as flash programming, boundary scan, and real-time data inspection, developers can identify and rectify issues rapidly, streamlining the development lifecycle. This robustness is significant for minimizing downtime, which can be costly for projects with tight deadlines.

For enhanced performance, the HQ-ST Link integrates seamlessly with various Integrated Development Environments (IDEs), including popular platforms like Keil, IAR, and STM32CubeIDE. This compatibility allows developers to leverage the advanced features of modern IDEs, enhancing productivity and workflow.

Moreover, user-friendly documentation and community support further augment the HQ-ST Link's appeal. Developers can readily access resources and support, which facilitates a smoother learning curve and troubleshooting process. The emphasis on community engagement helps foster innovation as users share tips and techniques.

In summary, the Lava Computer HQ-ST Link combines advanced technology with user-friendly features, making it a powerful tool for embedded systems developers. Its compatibility with multiple microcontroller families, support for various debugging interfaces, fast USB connectivity, and seamless integration with leading IDEs position it as a premier choice in the market for programming and debugging solutions.