PLANNING YOUR INSTALLATION

COMBUSTIBLE WALL CLEARANCE

WARNING: IT IS VERY IMPORTANT THAT YOU OBSERVE THE MINIMUM CLEARANCES.

There are listed clearances for your stove which were determined in a Laboratory test using various "classes" of stove pipe or chimney. Minimums are first estab- lished for the stove itself and increased based on how much heat is transferred by each class of pipe.

Note: Manufactured (mobile) home installations require the use of a Type L Vent Chimney connector only. Use of a single wall flue pipe connection is not permitted.

UNITED STATES REQUIREMENTS

Residential Reduced Clearance

Use listed double wall chimney connector or Type L vent pipe to the top of the stove. Clearances (Inches):

A. 13.6"

C. 15"

E. 15" *

B. 25"

D. 6"

F. 5" *

RESIDENTIAL STANDARD

Does not apply to manufactured (mobile) home in- stallations. Using single wall connector pipe from the stove top up to the chimney support box. Clearances (inches):

A. 21.6"

C. 18"

E. 15" *

B. 25"

D. 13.75"

F. 7.75" *

MANUFACTURED (MOBILE) HOME CLEARANCE NOTE: Manufactured (Mobile) home installations re- quire the use of a double wall chimney connector be- tween the stove and the chimney as specified below. Use of a single wall flue pipe connection is not permit- ted. Chimney must be Simpson Dura-Vent Dura/Plus chimney with manufactured (mobile) home installation kit (Dura-Vent part number 6DP-MH). Chimney connec- tor between stove and chimney must be Simpson Dura- Vent DVL close clearance connector pipe. Manufac- tured (Mobile) Home installations must use a rain cap with a spark arrester. Clearances (Inches):

A.13.6"

C.15"

E. 15" *

B.25"

D. 6"

F. 5" *

PROTECTED WALL CLEARANCE

Some local codes will allow reduced clearances when the stove is installed adjacent to a protected wall system. The variance must be approved by your local building official. Normally, the protected wall system is defined as a non- combustible material with a minimum of 1" air space be- hind. Check your local building codes or with a qualified installer (Ref. NFPA 211).

CANADA REQUIREMENTS

This appliance is not approved for installation into a manufactured (mobile) home in Canada.

Residential Reduced Clearance

Use listed double wall chimney connector or Type L vent pipe to the top of the stove. Clearances (Centimeters):

A. 44.5 cm

C. 40.5 cm

E. 51.0 cm *

B. 76.0 cm

D. 25.5 cm

F. 15.0 cm *

Residential Standard

Using single wall connector pipe from the stove top up to the chimney support box. Clearances (Centimeters):

A. 62.5 cm

C. 53.5 cm

E. 51.0 cm *

B. 76 cm

D. 42.5 cm

F. 27.5 cm *

Corner Installation

Parallel Installation

*Note: E and F dimensions are measured to side of stove below the projection of outer top.