READ ALL ThE STEPS BEFORE STARTING ThE CONVERSION.
INSTALLER NOTICE: ThESE INSTRuCTIONS MuST BE LEFT wITh
ThE APPLIANCE.
This kit contains components required to convert this appliance
from using Propane Gas to using Natural Gas as the only fuel.
All of these components must be replaced in order for the unit to
operate safely on Natural Gas.
when installing gas components use pipe joint compound or
Teflon tape on all pipe fittings before installing (ensure propane
resistant compounds are used, do not use pipe joint compounds
on flare fittings).
INSTALLATION INSTRuCTIONS
TuRN OFF ThE GAS SuPPLy TO ThE APPLIANCE.
Step 1. Using a Torx T20 or flat screwdriver, remove the Nova SIT LP
Regulator (flame height control) by removing the 3 screws sur-
rounding it (see Figure 3) . Be sure to also remove the LP regulator
diaphragm (see Figure 3).
Step 2. Install the Nova SIT NG Regulator (included in this kit) using the
3 new screws provided as shown in Figure 3.
Diaphragm
Screws
Regulator
Pressure
Regulator
Remove
These
Components
Figure 3
Fill out & affix label from
regulator kit to valve
Step 3 Remove the glass by releasing the two upper spring latches, and
lifting up and out of the lower latches.
Step 4 Remove the right side burner support by removing the four allen
screws (see Figure 4). Note: The right front corner of the burner
shares a screw with the burner support.
Step 5 Remove the allen screw securing the front left corner of the
burner.
Step 6 Move the air shutter control lever all the way to the right (see
Figure 9).
Step 8 Remove the pilot shield by removing the two allen screws (see
Figure 5).
Step 9 Reinstall screws to secure pilot assembly for pilot orifice conver-
sion.
5/32” allen screws
Figure 4
Figure 5
Shared Screw hole
Step 7 To remove the burner, slide the burner off the orifice and out of
the air shutter by shifting the burner to the right.
Remove the allen
screw securing the
front left corner of
the burner.
Burner
Remove the allen
screws on the right
side of burner.
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.
2