Lennox Hearth E42ODG Electronic Pilot, Sensor, Ignitor, Electronic Appliances, Refer to Figure

Models: E42ODG E36ODG

1 2
Download 2 pages 30.61 Kb
Page 2
Image 2
Remove Clip

Pilot Stage

Terminal

Ground (TP)

TP

Gas Outlet Shutter

To Burner

Pressure-Tap (Inlet)

 

IN

TH TP

 

LO

HI

TH

OUT

 

 

VENT

Pilot Gas

Outlet

PILOT

IN

Supply Gas Inlet

Use pipe joint compound or Teflon tape on all pipe fittings before installing (ensure propane resistant compounds are used in propane ap- plications, do not use pipe joint compounds on flare fittings).

Remove Tube

Remove Clip
Shutter
Opening

Burner Stage

Regulator

Pressure-Tap

Terminal

Mounting Screw

(Manifold)

Figure 2

ELECTRONIC PILOT

 

 

Pilot

Sensor

Hood

Ignitor

 

PROPANE

NATURAL

Note: If the ignitor is damaged, a replacement kit is available, order Catalog Number 87L54.

Figure 3

Electronic Appliances

Step 4. Dexen Electronic Valves - See Figure 2 and the instructions provided with the kit. Re- move and discard the two pressure regulator mounting screws. Remove the pressure regu- lator and diaphragm. Discard all removed components. Ensure the provided diaphragm is installed properly onto the replacement pres- sure regulator and install the new pressure regulator using the new screws supplied with the kit. Tighten screws.

See Figure 3 and replace the pilot orifice as follows: Remove pilot hood assembly to access the pilot orifice. Remove and replace the orifice with the one provided with the kit. Exercise extreme care to prevent damage to or break- age of the ignitor assembly.

Step 5. (Refer to Figure 5 )

A. Remove the orifice from the manifold and replace it with the one provided in the kit. See the following table for orifice sizes for natural and propane models. Figure 4 illustrates the orifice.

B. Retrieve the burner and slide the venturi tube over the orifice. Set the shutter adjusting opening as shown in Figure 5.

Model No.Orifice size

 

 

Natural

Propane

 

 

 

 

All Models

#28

#47

0.1405

0.0785

 

 

 

 

Figure 4

Step 6. Reassemble the remaining compo- nents by reversing the procedures outlined in the preceding steps.

OrificeRegulator

 

 

 

 

 

MAIN BURNER

 

FACTORY SHUTTER OPENING SETTING

 

 

 

 

Models

Natural Gas

 

Propane Gas

inches (mm)

 

inches (mm)

 

 

 

 

 

 

All

1/16 (1.58)

 

1/2 (12.7)

Models

 

 

 

 

Figure 5

 

 

 

Step 7. Attach appropriate conversion kit label (Figure 6 ) to the rating plate on the appliance.

THIS APPLIANCE HAS BEEN CONVERTED TO:

NATURAL GAS

INPUT BTU/HR –

MANIFOLD PRESSURE –

ORIFICE SIZE –

THIS APPLIANCE HAS BEEN CONVERTED TO:

PROPANE/LPG

INPUT BTU/HR –

MANIFOLD PRESSURE –

ORIFICE SIZE –

Figure 6

Step 8. Turn on gas supply and test for gas leaks, using a soapy water solution.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

Printed in U.S.A. © 2006 by Lennox

LHP

1110 West Taft Avenue

P/N 750,222M REV. A 07/2006

Orange, CA 92865

Page 2
Image 2
Lennox Hearth E42ODG Electronic Pilot, Sensor, Ignitor, Electronic Appliances, Refer to Figure, 1/16, Orange, CA, Shutter