Lennox Hearth E36ODG manual In Canada, AND .2 INSTALLATION CODE, Gas Conversion Kit, 750,222M

Models: E42ODG E36ODG

1 2
Download 2 pages 30.61 Kb
Page 1
Image 1
GAS APPLIANCE

GAS APPLIANCE

KITS AND ACCESSORIES

750,222M

GAS CONVERSION KIT

REV. A 07/2006

 

 

 

WARNING: THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S IN- STRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORIZED HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS NOT PROPER AND COM- PLETE UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT. THE QUALIFIED SERVICE AGENCY PERFORMING THIS INSTALLATION ASSUMES RESPONSIBILITY FOR THIS CONVERSION.

AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISÉSAVOIRLAJURIDICTION. SIL'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE PROTOXYDEDECARBONEPEUTRÉSULTERLEDOMMAGES CAUSER DE PROPRIÉTÉ, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL CONVERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS DANS LES INSTRUCTIONS DE PROPRIÉTAIRE PROVISIONNÉES AVEC L'ÉQUIPEMENT.

In Canada:

THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1

AND .2 INSTALLATION CODE.

LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX RECOMMANDATIONS DES AUTORITÉS PROVINCIALES AYANT JURIDICTION ET CONFORMÉMENT AUX

Step 1. Turn off the gas supply to the appli- ance and disconnect the electrical power.

Step 2. Carefully remove the logs. Exercise care so as not to break the logs. Remove any lava rock within the burner pan.

Step 3. Remove the burner tube with attached venturi tube. Refer to Figure 1 for the location of the control valve and regulator, main orifice and pilot.

Gas Conversion Kits

Models

LP To Nat

Nat To LP

 

 

 

E36ODG

Catalog No.

Catalog No.

E42ODG

H4915

H4916

 

 

 

E36ODG

Model No.

Model No.

E42ODG

GCK-DB140N

GCK-DB078P

 

 

 

EXIGENCES DU CODE D'INSTALLATION CAN1- B149.1 ET.2.

Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the nec- essary components needed to complete the task including labeling that must be affixed to ensure safe operation.

Kit part numbers are listed here and the follow- ing steps detail the conversion procedure.

CAUTION: THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DISCONNECTING THE ELEC- TRICAL POWER, BEFORE PROCEEDING WITH THE CONVERSION.

 

Pilot Orifice

Burner Tube

Main

 

 

Orifice

 

 

Access

 

 

Cover

 

 

 

Control Valve

 

Figure 1

And Regulator

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Page 1
Image 1
Lennox Hearth E36ODG, E42ODG manual In Canada, AND .2 INSTALLATION CODE, EXIGENCES DU CODE DINSTALLATION CAN1- B149.1 ET.2