Manual-Reset Safety Limit Switch

This appliance is equipped with a manual- reset blocked flue safety limit switch. Refer to Figure 5 for its location. If, during appliance operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the operation of this safety limit switch. First allow the appliance to cool, then reset the safety switch by pushing the red reset button on it.

A- To access the blocked flue safety switch when top radiant panel is not covered with non-combustible material:

1- Lift up and remove top radiant panel/ eyebrow assembly on the control side of unit.

2 - Reach between the cabinet side and the firebox side wall and locate the blocked flue safety switch.

3 - Push the red reset button on the switch.

The applilance should then relight and remain lit. If this does not occur, turn off the appli- ance and call a qualified service technician.

B- To access the blocked flue safety switch when top radiant panel is covered with non- combustible material:

Note: This procedure should only be performed by a qualified service technician.

1- Lower bottom hinged panel on the con- trol side of the fireplace. Remove the mod- esty panel and glass enclosure panel as described on page 8, under "Remove the front glass enclosure panel as follows:", Steps 2, 3, 4, 5 and 6.

2 - Remove the side baffle securing screws

(5) and then remove the baffle.

3 - Remove the safety switch bracket secur- ing screws (2), and pull the switch/bracket assembly through the side panel slot.

4 - Push the red reset button on the switch. 5 - Reinstall the switch/bracket assembly. 6 - Reinstall the side baffle.

7 - Reinstall front glass door.

8 - Raise the bottom hinged panel.

The appliance should then relight and remain lit. If this does not occur, check unit for a blocked flue condition.

Maintenance

The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techni- cian. However, more frequent periodic inspec- tions and cleanings should be performed by the homeowner. Homeowner must contact a qualified service technician at once if any abnormal condition is observed.

Refer to the maintenance schedule for mainte- nance tasks, procedures, periodicity and by whom they should be performed. Always verify proper operation of the appliance after servicing.

IMPORTANT: TURN OFF GAS AND ANY ELEC- TRICAL POWER BEFORE SERVICING THE APPLIANCE.

Front Glass Enclosure Panel, Removal and Installation.

WARNING: NEVER OPERATE THE APPLI- ANCE WITHOUT THE GLASS ENCLOSURE PANELS IN PLACE AND SECURE. DO NOT OPERATE APPLIANCE WITH FRONT GLASS CRACKED, BROKEN OR MISSING. REPLACE- MENT MUST BE DONE BY A LICENSED OR

6

SAFETY SWITCH LOCATION (EBCL-2 SHOWN)

EBST-2 and EBPF-2 Safety Switch Location Also as Shown; EBCR-2 Location

on Left End of Fireplace, EBBAY Location on The Rear of Fireplace.

 

FIREBOX SIDE BAFFLE SECURING SCREW

FIREBOX BOX

FIREBOX SIDE BAFFLE

SIDE WALL

 

MANUALLY-RESET

SAFETY LIMIT SWITCH

SAFETY SWITCH

BRACKET SECURING SCREW

TOP RADIANT PANEL

AND EYEBROW

CABINET SIDE WALL

Figure 5

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

QUALIFIED SERVICE TECHNICIAN.

These fireplaces are designed to operate only with the glass enclosure panels properly in- stalled. Generally the glass enclosure panels should not be removed except to gain access to the components within the firebox, and the appliance may only be operated without the front glass enclosure panel in place for very brief periods of time during initial appliance checkout and adjustment.

During this appliance checkout and adjustment period, a potential safety hazard exists - EXER- CISE EXTREME CAUTION to prevent the occur- rence of any burn injuries from the exposed flames or hot surfaces. Also note, that while the front glass enclosure panel (or any of the panels) is removed, the flame appearance will appear to be smaller than normal.

WARNING: HANDLE THE GLASS WITH EX- TREME CARE! TEMPERED GLASS IS SUS- CEPTIBLE TO DAMAGE (SCRATCHES, FOR EXAMPLE) – HANDLE GLASS DOOR (GLASS ENCLOSURE PANEL) GENTLY WHILE REINSTALLING IT.

Page 6
Image 6
Lennox Hearth EBSTPM-2 Maintenance, Front Glass Enclosure Panel, Removal and Installation, Qualified Service Technician

EBSTNM-2, EBSTPM-2 specifications

Lennox Hearth is a reputable name in the heating and ventilation industry, known for producing high-quality, energy-efficient heating solutions. Among their impressive lineup, the EBSTPM-2 and EBSTNM-2 models stand out for their superior performance and innovative features.

Both models are designed to provide reliable warmth in residential settings while ensuring ease of use and energy efficiency. The EBSTPM-2 comes with a robust pellet-burning system, boasting a high-efficiency rating that ensures optimal heating output with minimal energy consumption. This model is particularly praised for its environmentally friendly operation, utilizing wood pellets as a renewable energy source.

The EBSTNM-2, on the other hand, features a natural gas burning system that offers convenience and clean-burning technology. With its powerful output and adjustable flame settings, users can customize their heating experience to suit their comfort levels. Both models showcase advanced combustion technology, which ensures that they operate efficiently while minimizing emissions and maximizing heat distribution throughout the space.

One of the key characteristics of the Lennox EBSTPM-2 and EBSTNM-2 is their sleek, modern design. They are constructed with high-quality materials that not only enhance durability but also complement various interior aesthetics. The intuitive controls are user-friendly, making temperature adjustments quick and easy.

Safety features are paramount in both models, with built-in mechanisms that prevent overheating and ensure safe operation. This highlights Lennox’s commitment to user safety and product reliability. For added convenience, both models are equipped with an automatic ignition system, allowing for a hassle-free startup process.

Finally, the compact size of the EBSTPM-2 and EBSTNM-2 makes them suitable for a range of spaces, ensuring that homeowners can enjoy efficient heating without sacrificing valuable room space.

In conclusion, the Lennox Hearth EBSTPM-2 and EBSTNM-2 are exemplary models that combine innovative technology, safety, and eco-friendliness. Their ability to provide consistent and efficient heat makes them ideal choices for homeowners looking to enhance their comfort while also being mindful of energy consumption and the environment.