8NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Clearances to Combustibles
Minimum clearances to combustible materials in inches
(millimeters):
Parallel Installation
Corner Installation
Alcove dimensions
The minimum width between the alcove side walls is 48”
(1219mm). The minimum height of the alcove is 69” (753mm)
and the maximum depth is 48” (1219mm).
Floor Protection
A noncombustible hearth pad is not required. This stove
may be installed on a combustible surface. Also, the floor
beneath the stove must be stable, level, hard and strong
enough to support the stove without a tipping hazard.
48”
(1219mm)
Min.
48”
(1219mm)
Max.
69”
(753mm)
Min.
Alcove Dimensions
24-1/2”
(622mm)
Min.
12-1/2”
(318mm)
Min.
4” (102mm)
4-1/2”
(114mm)
Min.
4-1/2”
(114mm)
Min.
10-1/2”
(267mm)
Min.
90°
Figure 3
Figure 4
Figure 5
Pipe Clearances
All installations using a vertical termination cap must
maintain one inch clearance between the direct vent pipe
and combustibles. For horizontal runs of pipe, one inch of
clearance to combustibles on the sides and bottom and two
inches on the top of the pipe is required. See Page 16 for
allowable pipe configurations.