Insulated Chase Construction
Roof Support
Attic Radiation
Shield
Note: Floor and wall below the attic must be insulated using the same insulation.
|
| Firestop |
|
| 6’ 8” |
|
| (2 m) |
| 7’ | Min. |
| (2.1 m) | FIREPLACE |
| Min. | |
|
| |
Figure 9 | 1/2” Plywood |
Storm Collar
Flashing
Floor
Ceiling
Wall
• Must have the same firestopping resistance as adjacent wall.
•Must have the same insulation as adjacent ceiling.
•Follow local rules regarding framing construction.
8’8'
(2.Level4 m)
Level
Drywall or Any Rigid
Material
2 x 4 | Insulation | |
(Thermal Barrier) | ||
|
Optional
Insulation
In Outside
Walls Of
Chase
Solid
Continuous
Surface
Outside
Base
Facing
1.Combustible material must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) (Figure 10).
2.
Mantel and Facing
The mantel must be installed at least 39’’ (990
mm)above the base of the fireplace (Figures 7b and 11).
Fireplace Frame Section
(Top View)
3
1 | 4 |
|
5
2
1.Fireplace
2.Tiling flange
3.Wood frame (2” x 3” min)
4.Drywall
5.Tiles or brick
Figure 10
Mantel and Facing (Side View)
Mantel Drywall
2” X 3” Min.
(51mm x 76mm)
Spacer 39’’ (990 mm)
Rock Board or Other
Noncombustible Facing
Drywall
Rock Board or Other
Noncombustible
Facing
Figure 11
10 | NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. |