Only
38”
(965mm)
Min.
Figure 12
Noncombustible Facing
Drywall
2” X 3” Min.
Spacer
Rock Board or Other
Figure 13
Fireplace Blower
The fireplace is equipped with a blower. It is located in the bottom of the fireplace towards the back. It uses 120V and must be connected to the main electrical circuit by a qualified electrician prior to enclosing the fireplace.
For connection, use the electrical box supplied with the unit located on the bottom right side of the fireplace. To access the electrical box remove the four screws, pull out the plate and box and install the electrical receptacle.
A wall on/off switch must be installed to control the blower. An optional heat switch and variable speed control are available (see Page 22).
If installed, the heat activated switch must be connected to the blower main cable and the magnets must be stuck under the fireplaces firebox accessible through the side electrical box access plate.
If a repair must be done after the fireplace is installed an access plate is located under the bottom refractory. Remove the bottom refractory, unscrew the access plate, clean black cement sealing the access plate and do the repair.
Once the repair is done, it is mandatory to |
| ||
apply a new high temperature black cement | Frame | ||
| |||
sealing the access plate and all screw holes. | Grill | ||
Because the Ladera fireplace is an air tight |
| ||
fireplace, failure to do so will reduce fireplace |
| ||
efficiency. Tightly screw the access plate back |
| ||
on place and reinstall the bottom refractory. |
| ||
|
| WARNING: Both pipes of | |
HOT AIR DUCTING INSTALLATION | the double hot air outlet | ||
The Ladera™ fireplace is approved for use with | must be installed. Any oth- | ||
er installation may cause | |||
a Gravity kit (hot air ducting system). | |||
fire and void warranty. | |||
|
| ||
Gravity Kit |
| ||
The gravity kit is designed for double hot air |
| ||
outlets and includes: (See Figure 14). |
| ||
- | Two (2) telescopic lengths 8” I.D. |
| |
- | Two (2) 90º elbows 8” I.D. |
| |
- Two (2) hot air outlet kits |
| ||
| (grill and frames) |
| |
- | Two (2) adaptors |
| |
See Gravity Kit Accessories Page 22. | Figure 14 | ||
For safe installation, the gravity kit must meet | |||
| |||
the following requirements: |
| ||
Minimum height* 68” (1,727 mm) |
| ||
Maximum length See Figure 15 | When installing the double outlet system, the | ||
* The height of the louver must be measured | |||
hot air outlets can be installed in the same room | |||
from the base of the Ladera fireplace to the | as the fireplace, or one or both of the outlets | ||
middle point of the louver. | can be installed in adjacent or upper rooms. | ||
The only blower that can be used with the gravity | |||
Installing the ducts at different elevations will | |||
kit is the one sold with the fireplace. | tend to exhaust more heat out of the higher | ||
To extend the double outlet system, it will be | outlet (Figure 15). | ||
necessary to purchase two adjustable lengths |
| ||
(7B26ZL2A). |
|
WARNING: The outlet grills
should not be installed fac- Outlet Grill ing upward through a floor.
Danger of burns can result if grills in floor are stepped on.
|
| 10’ |
| 13” x 13” | (3.1m) |
| Max. | |
Outlet Grill | ||
| (330mm x 330mm) |
|
|
|
10’ (3.1m)
Max.
Maintain at least
Figure 15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. | 11 |