Adaptor

Insulated

Flex Pipe

Figure 17

Insulation

Blower

Flex 5” Diameter

 

Aluminum Tape

Tightening Collar

Figure 18

OUTSIDE AIR KIT (fireplace and AC chimney)

The outside air kit is optional on the Ladera™ fireplace, but mandatory on the AC chimney. It can be burned drawing air only from the house. When the fireplace is in operation with the door closed, it will pull only a slight amount of air from the house. Nevertheless, the outside air kit might be mandatory in your jurisdiction, check your local building code.

To install an outside air intake on the fireplace:

1. Remove the obstruction plate and the access plate (both are super- impose) located on the bottom of the left side (Figure 19, part 2).

2.Screw the obstruction plate inside the primary air box using only two screws on the bottom (Figure 19, part 3).

3.Reinstall the access plate exposing the 5 inch diameter hole topped

by a triangle (Figure 19, part 4).

Figure 19

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.