ANGLED WALL RADIATION SHIELD (RSM+ and RSMI30)

When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required.

Note: 45º angle for Canada only (RSMI45)

In cold climate locations (climates where temperatures will fall below 32° F / 0° C), we recommend that you use the insulated wall radiation shield since it will maintain the home’s thermal barrier.

RSM+ and RSMI30

(RSMI45 - Canada Only)

Insulated Wall

Drywall

Chimney Model

Angle

Hole Size

 

 

 

ASHT+ / HT6103+

30º

283 mm x 781 mm (11-1/8” x 30-3/4”)

(6” dia). Canada only

 

 

45º

283 mm x 518 mm (11-1/8” x 20-3/8”)

 

 

 

 

S-2100+ / HT6000+ /

30º

327 mm x 881 mm (12-7/8” x 34-11/16”)

AC (6” dia).

 

 

30º

380 mm x 972 mm (15” x 38-1/4”)

 

 

 

 

Table 5

Figure 31

Insulated Wall Radiation Shield

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.