CHIMNEY SUPPORT INSTALLATION

Universal Roof Support

This support has three possible uses:

1.For ASHT+ / HT6103+ and S-2100+ / HT6000+, it must be used on a roof to support the chimney.

2.It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.

3.It may be used on a floor, ceiling or roof as a supplementary sup- port.

Table 6 gives maximum height of supported chimney.

NOTE: For the AC chimney, a support section must be used every forty (40) feet (12 m) instead of the universal roof support (ST).

For roof support installation, refer to the instructions provided with the support.

Universal Offset Support

This support is used to support the chimney above an offset. When the chimney offset is used to traverse a wall this support may be used on the wall to support the chimney. The maximum heights are given in Table 6. For offset support installation, refer to the instructions provided with the support.

CHIMNEY MODEL

MAXIMUM HEIGHT OF

 

SUPPORTED CHIMNEY

 

Offset Support

Roof Support

 

 

 

ASHT+ / HT6103+ (6” dia).

28 feet (8.54 m)

29 feet (8.84 m)

 

 

 

S-2100+ / HT6000+ (6” dia).

18 feet (5.49 m)

20 feet (6.1 m)

 

 

 

AC (6” dia).

40 feet (12.19 m)

50 feet (15.20 m)

 

 

 

Table 6

CHIMNEY CHASE AND MULTIPLE TERMINATIONS

For the purpose of this manual, a chimney chase is considered a part of the chimney system rather than part of a building. The termination must be placed a minimum of 18” (460 mm) above the chase.

For installations where more than one chimney is located in the same chase or within the same area, we suggest that their terminations be separated by at least 16” (410 mm) horizontally, and 18” (460 mm) verti- cally. This separation is to prevent smoke migrating from one chimney to another (see Figure 32).

18” (460 mm)

 

 

18” (460 mm)

 

 

 

 

 

 

 

 

 

 

16” (410 mm)

16” (410 mm)

18” (460 mm)

 

Figure 32

CHIMNEY ADAPTOR (S-2100+ / HT6000+) CANADA ONLY

The fireplace is supplied with a chimney adaptor suitable for the ASHT+ / HT6103+ chimney. If you want to install a S-2100+ / HT6000+ chimney, an adaptor is available (6UCA) (Figure 33). A separate starter section will also be required if AC chimney is installed.

Chimney Adaptor -

Canada only

Figure 33

20