OPTIONal installation accessories
Installation Accessories
Description | Cat./ Part No. |
|
|
Outside Air Kit
Outside Air Coupler To Connect Outside Air (UZI) To Fire- | UZIAD | |
place, UZIAD |
|
|
|
| |
Outside Air Ducting - includes 4” insulated flex x 10’ long, UZI | UZI | |
|
|
|
| Gravity Kit |
|
|
| |
Complete double ducting system including: 2 elbows 90º, 2 | ||
telescopic lengths, 2 grill supports and 2 black grills |
| |
|
|
|
| Gravity Kit Accessories |
|
|
| |
Black grill with support, Part# 7B30ZO | 7B30ZO | |
|
| |
Brass grill (for 7B30ZK), 7B30ZGB | 7B30ZGB | |
|
| |
Elbow 90º, 8” dia., 7B26ZE90 | 7B26ZE90 | |
|
| |
Elbow 45º, 8” dia., 7B26ZE45 | 7B26ZE45 | |
|
| |
Telescopic length, 8” dia., 7B26ZLA | 7B26ZLA | |
|
| |
Adjustable length 8” dia (2” - 5”), 7B26ZL2A | 7B26ZL2A | |
|
| |
Wall Radiation shield, 7B26ZR | 7B26ZR | |
|
| |
Length five (5) feet, 8KL5 | 8KL5 | |
|
| |
Length four (4) feet, 8KL4 | 8KL4 | |
|
| |
Length three (3) feet, 8KL3 | 8KL3 | |
|
| |
Length two (2) feet, 8KL2 | 8KL2 | |
|
| |
Length one (1) feet, 8KL1 | 8KL1 | |
|
|
|
| Fireplace Kits |
|
|
|
|
Rigid firescreen |
| BNZN |
|
| |
Central Forced Air Kit Accessories u |
| |
Central Forced Air Kit, Central forced air kit including: blower | ||
(BISZY), flex adaptor (BISAF), 2 clamps, variable speed |
| |
control (VRUW), |
| |
adapter (BISAVF), back draft damper (BISBD), aluminium |
| |
tape, |
|
|
|
| |
Fireplace to Flex adaptor and 2 clamps, BISAF | BISAF | |
|
|
|
Flexible pipe 5” I.D. x | 15 ft. Long, 5FLEX15 | 5FLEX15 |
|
|
|
Flexible pipe 5” I.D. x | 30 ft. Long, 5FLEX25 | 5FLEX25 |
|
| |
Blower 250 CFM for central forced air kit, BISZY | BISZY | |
|
| |
Blower variable speed control with decorative wall plate for | VRUW | |
(BISZY), VRUW |
|
|
VTU | ||
|
| |
Blower to flexible pipe adaptor, BISAVF | BISAVF | |
|
| |
Heating and cooling thermostat, HCTW | HCTW | |
|
| |
Backdraft damper, BISBD | BISBD | |
|
|
|
uNot tested under EPA certification. If installed, this appliance no longer qualifies for EPA certification.
| Fireplace Model Ladera - Approved Venting Components manufactured |
| by Security Chimneys International only. |
| • 6” diameter chimney - AC (air cooled), Secure Temp™ ASHT+ (or Nova |
| Temp™ HT6103+) and Secure Temp |
| • 6” diameter chimney for relining masonry chimneys - TUBINOX chimney (or |
| PROJET SS), 6” diameter with adaptor for installation in a masonry chimney. |
22 | • 7” diameter chimney - Secure Temp™ ASHT+ (or NovaTemp™ HT6103+). |
|
Cast Surround Kit
Description | Cat./ Part No. |
|
|
Cast Surround Kit, | H7303 |
|
|
Chimney - PARTS AND COMPONENTS LISTs
Secure Temp ASHT 1” High Temp. Insulated Stainless Steel Chimney
6” I.D. and 8” O.D.,
Description | Part/Cat. No. |
|
|
Lengths and Misc. Chimney Components | |
|
|
8” length, 6” Dia., 6L8 | 6L8 |
|
|
12” length, 6” Dia., 6L12 | 6L12 |
|
|
18” length, 6” Dia., 6L18 | 6L18 |
|
|
24” length, 6” Dia., 6L24 | 6L24 |
36” length, 6” Dia., 6L36 | 6L36 |
|
|
48” length, 6” Dia., 6L48 | 6L48 |
Adjustable Length 12”, 6” Dia., 6LA | 6LA |
|
|
15º elbow, 6” Dia., 6E15 | 6E15 |
30º elbow, 6” Dia., 6E30 | 6E30 |
|
|
Rain Termination Cap, 6” Dia., 6CC | 6CC |
|
|
Spark Arrester Screen (universal spark arrester band), PE | PE |
|
|
Wall Band, BM | BM |
|
|
Supports |
|
|
|
Offset Support, SO | SO |
|
|
Roof Support, ST | ST |
|
|
Roof Brace, BS2 | BS2 |
|
|
Firestops |
|
|
|
Firestop, 6BF | 6BF |
|
|
Radiation Shield, 6RS | 6RS |
|
|
Insulated Attic Radiation Shield, 6RSA | 6RSA |
|
|
Insulated Wall Radiation Shield, 6RSM | 6RSM |
|
|
Insulated Wall Radiation Shield, 30º, 6RSMI30 | 6RSMI30 |
|
|
Uninsulated Wall Radiation Shield, 30º, 6RSM30 | 6RSM30 |
Attic Radiation Shield | H0487 |
|
|
Roof Flashings |
|
Flat Roof Flashing, 6FR | 6FR |
|
|
1/12 - 7/12 (5º - 30º), 6FAR | 6FAR |
8/12 - 12/12 (30º - 45º), 6FBR | 6FBR |
|
|
Storm Collar, 6FC | 6FC |
|
|
Chimney Adaptors |
|
|
|
Chimney Adaptor, 6” (S2100, HT6000) | 6UCA |
|
|
Chimney Adaptor, 6 to 7” (ASHT, HT6103) | 6AW7 |
|
|
Notes:
jNova Temp HT6000+ is equivalent to Secure Temp
lThis appliance is equipped with the ASHT Chimney Adaptor. When other chimney is used, a chimney adaptor for that chimney will be required.
mChimney Adaptor
nAC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates (climates where temperatures will fall below 32° F / 0° C). When using AC chimney, an AC6SB starter section must be used before installing an elbow. When an offset is needed immediately off the top of the fireplace, an elbow starter section (AC6SB30) is available.
oChimney Adaptor 7in - If you want to install a 7in ASHT / HT6103 chimney, an adaptor is available (6AW7).